4 lines
2.6 KiB
Plaintext
4 lines
2.6 KiB
Plaintext
|
||
|
||
|
||
|
||
|
||
4045XLPStream Test Log
|
||
Interlisp-D Version: Lyric
|
||
|
||
|
||
|
||
|
||
|
||
|
||
Author: Peter Reidy
|
||
Date: 18 March 1987
|
||
|
||
|
||
|
||
|
||
Xerox
|
||
Artificial Intelligence Systems
|
||
|
||
|
||
The procedure {ERIS}<LISPCORE>test>hardcopy>4045xlpstream.proc was run from an 1109 through Centronics and TTY and from an 1186 and an 1109 through RS232. RS232 was successful except for an inability to print reversed sketches; attempts to print through Centronics caused a printer error (AR 7640). 1186/TTY has not been tried because the cabling spec was unavailable (AR 7698). A full regression test should be run once Centronics is fixed and 1186/TTY cabling is specified.
|
||
|
||
ARs SUBMITTED
|
||
(with status as of 18 March; includes ARs on comms packages)
|
||
|
||
7450: Lyric: 4045 prompt window printout should name files, not streams FIXED
|
||
7453: Lyric: need to document that 4045 doesn't print reversed sketches FIXED
|
||
7554: 4045XLPSTREAM doesn't mention need to configure the outlet on the back of the printer NEW
|
||
7634: 4045XLPSTREAM loads comms packages from LISPUSERSDIRECTORIES FIXED
|
||
7637: Need to warn 4045 users about AR 7634 DECLINED
|
||
7640: Printer error in 4045XLPSTREAM Centronics NEW
|
||
7641: Need to take Centronics out of Lyric 4045XLPSTREAM documentation DECLINED
|
||
7707: 4045XLPSTREAM Library Modules .01 in conflict with 1108 Users Guide .01 FIXED
|
||
7782: RS232: no printer response for 4045 FIXED
|
||
7824: Library Modules manual needs to tell users that DRAWARC isn't implemented for 4045XLPSTREAM. FIXED
|
||
7698: No documentation (version .01) on 4045-1186 TTY cabling. NEW
|
||
|
||
|
||
|
||
|