;DIAGNOSTIC CONSOLE HELP FILE, KLDCP.HLP, VER 20.7, 8-JANUARY-76 A. DIAGNOSTIC FUNCTIONS 1. FX FUNCT ;DIAGNOSTIC FUNCTION EXECUTE 2. FW FUNCT:DATA ;DIAGNOSTIC FUNCTION WRITE 3. FR FUNCT ;DIAGNOSTIC FUNCTION READ 4. FR FUNCT1,FUNCTX ;DIAGNOSTIC FUNCTION BLOCK READ 5. FS ;DIAGNOSTIC FUNCTION SYNC 6. DA DATA ;DIAGNOSTIC DEPOSIT INTO AR B. PDP-11 FUNCTIONS 1. SE ADR ;START 11 AT ADR SED ;START 11 DIAGNOSTIC (ADDRESS = 3000) SED # ;START 11 DIAGNOSTIC, RUN #PASSES 2. EE ADR ;EXAMINE 11 AT ADR AND PRINT 3. DE ADR:DATA ;DEPOSIT DATA IN 11 ADDRESS 4. EB ADR ;EXAMINE 11 BYTE AT ADR AND PRINT 5. DB ADR:DATA ;DEPOSIT 11 BYTE AT 11 ADDRESS 6. ZE ADR,ADR ;ZERO 11 MEMORY FROM ADR TO ADR C. PDP-10 EXAMINE/DEPOSIT FUNCTIONS 1. EM ADR ;EXAMINE PDP-10 AT ADR AND PRINT 2. DM ADR:DATA ;DEPOSIT DATA IN PDP-10 ADDRESS 3. EN ;EXAMINE AND PRINT NEXT PDP-10 ADDRESS 4. DN DATA ;DEPOSIT DATA INTO NEXT PDP-10 ADDRESS 5. MZ ADR,COUNT ;MEMORY ZERO PDP-10 D. START/STOP FUNCTIONS 1. SP ;STOP 10, CLEAR RUN FLOP 2. RN ;START 10, SET RUN FLOP 3. SI ;SINGLE INSTRUCT, PUSH CONTINUE BUTTON SI NUM ;DO NUM SINGLE INSTRUCTS 4. SIP ;SINGLE INSTRUCT & TRACE PRINT 5. PL ;PULSE CLOCK 6. PL NUM ;DO NUM CLOCKS 7. BU ;BURST CLOCK ONCE 8. SM NUM ;BURST CLOCK NUM 9. SM ;START MICRO-CODE 10. ST ADR ;START 10 AT ADDRESS ST ;START 10 AT PREVIOUSLY SUPPLIED ADDRESS STD ;START 10 DIAGNOSTIC, (EPT ADR = 440) STD # ;START 10 DIAGNOSTIC, RUN # PASSES STL ;START 10 LOADER, (EPT ADR = 442) DDT ;START 10 DDT, (EPT ADR = 441) STM ;START 10 MONITOR, (EPT ADR = 443) 11. MC ;PDP-10 MONITOR MODE CONTINUE 12. SW DATA ;SET 10'S SWITCH REGISTER 13. SW ;PRINT PRESENT 10'S SWITCH REGISTER 14. AC BLK ;REPORT & SELECT CURRENT AC BLOCK 15. AC BLK NUM ;SELECT CURRENT AC BLOCK 16. EP COUNT ;SET "EOP" INTERVAL COUNT E. RAM FUNCTIONS 1. EC ADR ;EXAMINE C-RAM AT ADDRESS AND PRINT 2. DC ADR:DATA ;DEPOSIT DATA INTO C-RAM ADDRESS 3. RC ADR ;READ C-RAM BY DIAGNOSTIC FUNCTIONS 4. ED ADR ;EXAMINE D-RAM AT ADDRESS AND PRINT 5. DD ADR:DATA ;DEPOSIT DATA INTO D-RAM ADDRESS 6. MM ADR ;SYNC MARK MICRO-CODE, SET BIT 78 7. MU ADR ;SYNC UNMARK MICRO-CODE, CLEAR BIT 78 8. MT ADR:DATA ;CHANGE MICRO-CODE TIME FIELD, DATA=0-3 F. PDP-10 INSTRUCTION EXECUTE 1. EX INST ;EXECUTE 36 BIT INSTRUCTION 2. EXP INST ;EXECUTE & PRINT INSTRUCTION 3. EXT INST ;EXECUTE & TRACE SETUP INSTRUCTION G. MASTER RESET 1. MR ;MASTER RESET H. CLOCK OPERATIONS 1. CS NUM ;SELECT CLOCK SOURCE USING NUM CODE ; 0=NORMAL CLOCK ; 1=SPEED MARGIN CLOCK ; 2=EXTERNAL CLOCK 2. CR NUM ;SELECT CLOCK RATE USING NUM CODE ; 0=NORMAL ; 1=DIVIDE BY 2 ; 2=DIVIDE BY 4 ; 3=DIVIDE BY 8 I. PROCESSOR PARITY FUNCTIONS 1. PE ;REPORT PROCESSOR PARITY STOP CODE 2. PE NUM ;ENABLE PROCESSOR PARITY STOPS 3. PD ;DISABLE PROCESSOR PARITY STOPS J. CACHE OPERATIONS 1. CE ;REPORT CACHE ENABLE CODE 2. CE NUM ;SELECT CACHE ENABLE OPTION 3. CI ;CACHE INVALIDATE 4. CF ;CACHE FLUSH K. INTERNAL EBOX REGISTER READ FUNCTIONS 1. AR ;READ & PRINT AR REGISTER 2. BR ;READ & PRINT BR REGISTER 3. MQ ;READ & PRINT MQ REGISTER 4. FM ;READ & PRINT FM REGISTER 5. AD ;READ & PRINT ADDER 6. ARX ;READ & PRINT EXTENDED AR REGISTER 7. BRX ;READ & PRINT EXTENDED BR REGISTER 8. ADX ;READ & PRINT EXTENDED ADDER 9. PC ;READ & PRINT PC 10. VMA ;READ & PRINT VMA 11. VMH ;READ & PRINT VMA HELD 12. SC ;READ & PRINT SC REGISTER 13. FE ;READ & PRINT FE REGISTER 14. ERG ;READ & PRINT E-BUS REGISTER 15. ADB ;READ & PRINT ADDRESS BREAK 16. PI ;READ & PRINT PI SYSTEM 17. ALL ;PRINT ALL, C-RAM & REGISTERS L. CONSOLE (TTY) CONTROL FUNCTIONS 1. TP NUM ;SET TTY PAGE LENGTH 2. TW NUM ;SET TTY PAGE WIDTH 3. TF NUM ;SET TTY FILL CLASS 4. TT ;SWITCH TO REMOTE TTY OPERATION 5. KLINIK ;REMOTE FS TTY ENABLE/DISABLE 6. LP ;LINE PRINTER SELECTION M. PROGRAM LOADING CONTROL FUNCTIONS 1. DT NUM ;SELECT DECTAPE LOAD MODE, ;NUM IS DECTAPE UNIT 2. RP NUM ;SELECT RP04 LOAD MODE, ;NUM IS RP04 UNIT 4. RX NUM ;SWITCH TO FLOPPY LOAD MODE, ;NUM IS FLOPPY UNIT 4. AT ;SWITCH TO APT10 LOAD MODE 5. DI ;DIRECTORY, DECTAPE/FLOPPY/RP04 N. PDP-11 BREAKPOINT OPERATIONS 1. BP ;PRINT ACTIVE BREAKPOINTS 2. BP ADR ;SET A BREAKPOINT AT ADDRESS 3. RG ;PRINT REGISTERS SAVED AT BREAKPOINT, ;ERROR HALT, PRG HALT OR FATAL HALT. 4. BC ;BREAKPOINT CONTINUE 5. BC COUNT ;BP CONTINUE FOR COUNT 6. RB ;REMOVE CURRENT BP 7. RB 0 ;REMOVE ALL BP'S 8. RB ADR ;REMOVE BP AT ADDRESS O. CONSOLE REINITIALIZATION 1. RI ;REINITIALIZE CONSOLE P. ERROR HALT CONTINUE 1. HC ;CONTINUE FROM ERROR OR PROGRAM HALT Q. REPEAT OPERATORS 1. R ;IF THIS IS THE FIRST COMMAND IN A ;COMMAND LINE, REPEAT THE COMMAND STRING ;CONTINUOUSLY. CONTROL C (↑C) RETURNS ;TO CONSOLE COMMAND MODE. 2. RP ;AS "R" COMMAND EXCEPT PRINTS THE DATA ;READ FOR READ TYPE COMMANDS. 3. TD COUNT ;PERFORM SPECIFIED TIME DELAY R. KL10 MONITOR COMMANDS 1. B ;BOOT SYSTEM, RUNS "B.CMD" AS "J" FILE 2. LI ;LOGIN 3. H ;HELP, PRINT "KLDCP.HLP" 4. H FILE.EXT ;HELP, PRINT REQUESTED FILE 5. P FILE.EXT ;LOAD REQUESTED PROGRAM ;EXTENSIONS ARE: ; .RAM = KL10 C-RAM & D-RAM ; .BIN = PDP-11 BINARY ; .A11 = PDP-11 ASCIIZED BINARY ; .A10 = PDP-10 ASCIIZED SAVE FILE ; .SAV = PDP-10 SAVE FILE, ACT10 ONLY ; DEFAULT EXTENSION IS ".A10" 6. LT FILE.EXT ;LOAD PDP-10 ".A10" PROGRAM 7. LE FILE.EXT ;LOAD PDP-11 ".A11" PROGRAM 8. LB FILE.EXT ;LOAD PDP-11 ".BIN" PROGRAM 9. LR FILE.EXT ;LOAD KL10 ".RAM" C-RAM & D-RAM 10. V FILE.EXT ;VERIFY REQUESTED PROGRAM, AS "P" EXCEPT ;CURRENT FILE IS VERIFIED AGAINST ;FILE BEING READ. N/A 11. S FILE.EXT ;RUN REQUESTED SCRIPT N/A 12. M FILE.EXT ;RUN REQUESTED MASTER SCRIPT 13. C MESSAGE ;COMMENT/CORRECTIVE ACTION R. KL10 MONITOR COMMANDS 14. GO ;GO START PROGRAM JUST LOADED 15. LO ;LOGOUT N/A 16. GS FILE.EXT ;GENERATE GIVEN SCRIPT 17. CD FILE.EXT SRTADR,ENDADR ;PDP-11 CORE DUMP TO DTA, RP04, ACT10 ; DEFAULT EXTENSION IS ".A11" 18. T ;REQUEST TIME 19. BT ;BOOT TEN, RUNS "BT.CMD" AS "J" FILE 20. ; ;LOCAL COMMENT 21. I FILE.EXT ;INDIRECT COMMAND FILE PROCESS ; DEFAULT EXTENSION IS ".CCL" 22. J FILE.EXT ;DOUBLE INDIRECT COMMAND FILE PROCESS ; DEFAULT EXTENSION IS ".CMD" 23. JC ;CONTINUE INTERRUPTED J FILE PROCESS 24. JR ;REPEAT PREVIOUS "J" COMMAND & CONTINUE 25. TA FILE.EXT ;TRANSFER FILE FROM ACT10 TO RP04 26. WF FILE.EXT ;WRITE FILE FROM DECTAPE/FLOPPY TO RP04 27. RENM:FILE.EXT FILE1.EXT ;RENAME RP04 FILE FROM FILE.EXT TO ;FILE1.EXT 28. DTCOPY ;COPY AND VERIFY DECTAPES 29. RXCOPY ;COPY AND VERIFY FLOPPY DISKETTES DTE20 DEVICE REGISTER AND BIT DEFINITIONS, 18-NOV-75 DTEADR= 174400 ;ADDRESS OF (FIRST) DTE20 DEVICE REGISTER BLOCK DTESIZ= 000040 ;SPACING BETWEEN CONSECUTIVE DTE20'S DTEMAX= 4 ;MAXIMUM NUMBER OF DTE20'S ON ONE PDP-11 ;OFFSETS FROM THE BASE OF THE DTE20 DEVICE REGISTER BLOCK ;TO SPECIFIC 10/11 INTERFACE RAM LOCATIONS AND REGISTERS. DLYCNT= 00 ;DELAY COUNT (ADDRESS XXXX00) DEXWD3= 02 ;DEPOSIT OR EXAMINE WORD 3 (ADDRESS XXXX02) DEXWD2= 04 ;DEPOSIT OR EXAMINE WORD 2 (ADDRESS XXXX04) DEXWD1= 06 ;DEPOSIT OR EXAMINE WORD 1 (ADDRESS XXXX06) TENAD1= 10 ;10 ADDRESS WORD 1 FOR DEX (ADDRESS XXXX10) TENAD2= 12 ;10 ADDRESS WORD 2 FOR DEX (ADDRESS XXXX12) TO10BC= 14 ;TO10 BYTE COUNT (ADDRESS XXXX14) TO11BC= 16 ;TO11 BYTE COUNT (ADDRESS XXXX16) TO10AD= 20 ;TO10 PDP11 MEMORY ADDRESS (ADDRESS XXXX20) TO11AD= 22 ;TO11 PDP11 MEMORY ADDRESS (ADDRESS XXXX22) TO10DT= 24 ;TO10 PDP11 DATA WORD (ADDRESS XXXX24) TO11DT= 26 ;TO11 PDP11 DATA WORD (ADDRESS XXXX26) DIAG1= 30 ;DIAGNOSTIC WORD 1 (ADDRESS XXXX30) DIAG2= 32 ;DIAGNOSTIC WORD 2 (ADDRESS XXXX32) STATUS= 34 ;10/11 INTERFACE STATUS WORD (ADDRESS XXXX34) DIAG3= 36 ;DIAGNOSTIC WORD 3 (ADDRESS XXXX36) ; THE FOLLOWING ARE THE ADDRESSES OF THE DTE20 INTERRUPT VECTORS DTEIV0= 774 ;INTERRUPT VECTOR FOR DTE20 #0 DTEIV1= 770 ;INTERRUPT VECTOR FOR DTE20 #1 DTEIV2= 764 ;INTERRUPT VECTOR FOR DTE20 #2 DTEIV3= 760 ;INTERRUPT VECTOR FOR DTE20 #3 ;CLOCK CONTROL FUNCTIONS STPCLK= 000 ; STOP CLOCK STRCLK= 001 ; START CLOCK SSCLK= 002 ; SINGLE STEP THE MBOX CLOCK SECLK= 003 ; SINGLE STEP EBOX CLOCK CECLK= 004 ; CONDITIONAL EBOX CLOCK CLRMR= 006 ; CLEAR MR RESET SETMR= 007 ; SET MR RESET BRCLK= 005 ; BURST THE CLOCK ;CLOCK LOAD FUNCTIONS LDBRR= 42 ; LOAD BURST REGISTER RIGHT HALF LDBRL= 43 ; LOAD BURST REGISTER LEFT HALF LDSEL= 44 ; LOAD SOURCE AND RATE SELECTS LDDIS= 45 ; LOAD EBOX CLOCK DISTRIBUTION REGISTER LDCHK1= 46 ; LOAD PARITY CHECK REGISTER (ENABLE BAD PARITY STOP) LDCHK2= 47 ; LOAD EBOX INTERNAL CHECK REGISTER ;DRAM FUNCTIONS LDRAM1= 60 ; LOAD A & B FIELDS EVEN LDRAM2= 61 ; LOAD A & B FIELDS ODD LDRAM3= 62 ; LOAD COMMON J1-J4 LDRJEV= 63 ; LOAD PARITY & J8-J10 EVEN LDRJOD= 64 ; LOAD PARITY & J8-J10 ODD DRAMAB= 133 ; READ D-RAM A & B DRJ710= 135 ; READ D-RAM J7-J10 DRJ1.4= 134 ; READ D-RAM J1-J4 ;IR DRAM CONTROL DISIOJ= 65 ; DISABLE 7XX & JRST=254 DISACF= 66 ; DISABLE THE IR AC'C ENIOJA= 67 ; ENABLE 7XX, JRST=254 & IR AC'S ;CRAM FUNCTIONS LCRAM1= 71 ; LOAD C-RAM DATA LCRAM2= 56 LCRAM3= 55 LCRAM4= 54 LCRAM5= 53 LCRDAL= 51 ; LOAD CRAM ADDRESS LEFT (00-04) LCRDAR= 52 ; LOAD CRAM ADDRESS RIGHT (05-10) RCRAM1= 147 ; READ C-RAM DATA RCRAM2= 146 RCRAM3= 145 RCRAM4= 144 ;MISC CONTROL FUNCTIONS IRLOAD= 14 ; LOAD THE IR FROM AD DRLTCH= 15 ; LOAD D-RAM LATCHES CLRRUN= 10 ; CLEAR RUN FLIP-FLOP SETRUN= 11 ; SET RUN FLIP-FLOP CONBUT= 12 ; THE CONTINUE BUTTON LDAR= 77 ; LOAD THE AR ;MBOX CONTROL FUNCTIONS LDMBXA= 57 ; LOAD MEMORY TO CACHE SELECTOR LDCHAN= 70 ; LOAD CHANNEL DIAGNOSTIC CONDITIONS ;PI CONTROL FUNCTIONS READ0= 100 ; PI (READ STATUS 0) READ1= 101 ; PI (READ STATUS 1) READ2= 102 ; PI (READ STATUS 2) READ3= 103 ; PI (READ STATUS 3) ;DATA PATH CONTROL FUNCTIONS DPAR =120 ; AR DPBR =121 ; BR DPMQ =122 ; MQ DPFM =123 ; FM DPFMA =114 ; FM ADR DPBRX =124 ; BRX DPARX =125 ; ARX DPADX =126 ; ADX DPAD =127 ; AD DPPC =153 ; PC DPVMA =157 ; VMA DPVMHD =157 ; VMA HELD DPADB =153 ; ADDRESS BREAK DPERG =167 ; E-BUS REGISTER DPFE =132 ; FE 05-09 DPFE1 =133 ; FE 00-04 DPSC =130 ; SC 05-09 DPSC1 =131 ; SC 00-04