DN92.DOC -- Changes from V7 to V10
|
||
January 1978
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
COPYRIGHT (C) 1977,1978 BY
|
||
DIGITAL EQUIPMENT CORPORATION, MAYNARD, MASS.
|
||
|
||
|
||
THIS SOFTWARE IS FURNISHED UNDER A LICENSE AND MAY BE USED AND COPIED
|
||
ONLY IN ACCORDANCE WITH THE TERMS OF SUCH LICENSE AND WITH THE
|
||
INCLUSION OF THE ABOVE COPYRIGHT NOTICE. THIS SOFTWARE OR ANY OTHER
|
||
COPIES THEREOF MAY NOT BE PROVIDED OR OTHERWISE MADE AVAILABLE TO ANY
|
||
OTHER PERSON. NO TITLE TO AND OWNERSHIP OF THE SOFTWARE IS HEREBY
|
||
TRANSFERRED.
|
||
|
||
THE INFORMATION IN THIS SOFTWARE IS SUBJECT TO CHANGE WITHOUT NOTICE
|
||
AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY DIGITAL EQUIPMENT
|
||
CORPORATION.
|
||
|
||
DIGITAL ASSUMES NO RESPONSIBILITY FOR THE USE OR RELIABILITY OF ITS
|
||
SOFTWARE ON EQUIPMENT WHICH IS NOT SUPPLIED BY DIGITAL.
|
||
DN9210.DOC Page 2
|
||
|
||
|
||
DN92.DOC -- Changes from V7 to V10
|
||
January 1978
|
||
|
||
|
||
|
||
1.0 SUMMARY
|
||
|
||
DN92 is a remote station on the DECsystem-10 network. It is a
|
||
sequential node based on a PDP8A processor. It was developed to
|
||
replace the DC72NP remote station.
|
||
|
||
The DN92 requires a DECsystem-10 with a DC75NP, DN85, DN87 or DN87S
|
||
front end, and a synchronous line between the front end and the DN92
|
||
It requires TOPS-10 version 6.02 or later monitors.
|
||
|
||
Specific documentation on the DN92 can be found in the Software
|
||
Notebooks write up entitled Networks and Software Guide and in the
|
||
file named DN92.RNO. The DN92.RNO file briefly describes the
|
||
differences in implementation of the software between the DC72NP and
|
||
the DN92.
|
||
|
||
|
||
|
||
2.0 EXTERNAL CHANGES
|
||
|
||
The DN92 is now being released through the Software Distribution
|
||
Center (SDC) and is no longer available as a special release. The
|
||
first version being released through SDC is version 10. Two other
|
||
versions have been distributed to the field, version 3 and version 7.
|
||
|
||
Changes have been made to version 10 which correct the following
|
||
problems:
|
||
|
||
1. The card reader was not sending the last column of a card to
|
||
the host (SPR 10-24343).
|
||
|
||
2. The line printer was not handling form control for the last
|
||
six lines on a page if they only contained CRLF'S (SPR
|
||
10-24343).
|
||
|
||
3. DN92 was not answering data sets reliably (SPR 10-24274).
|
||
|
||
4. Assembly errors if FTDEBUG=0 (SPR 10-2473).
|
||
|
||
5. Losing input on a high speed asynchronous line. The code was
|
||
changed to process a device control message which causes an
|
||
X-OFF character to be issued to the device as soon as
|
||
possible.
|
||
|
||
6. Error message for line printer was not being sent if it
|
||
occurred on initial output. The line printer routine was
|
||
modified to send an off-line status message.
|
||
|
||
7. DP8E bus errors were caused by the line printer routine
|
||
disabling the interrupt for too long when compressed
|
||
DN9210.DOC Page 3
|
||
|
||
|
||
characters were being flushed. Zeroing the repetitive
|
||
character count for flushed characters seemed the best
|
||
solution. Another solution is to stop the line printer, let
|
||
the flushed character time out, and the clock routine restart
|
||
output to the line printer. Hoewever, while eliminating all
|
||
bus errors, this solution seems to degrade the line printer's
|
||
performance and shouldn't be installed until the definite
|
||
problem exists.
|
||
|
||
8. The calculation for fill timing was modified to reflect the
|
||
real-time clock on the DN92 which interrupts every 10ms.
|
||
instead of every 16ms. (SPR 10-25554).
|
||
|
||
9. DAS92 station name was changed to DN92.
|
||
|
||
|
||
|
||
3.0 KNOWN BUGS AND DEFICIENCIES
|
||
|
||
The DN92 does not support trace feature DP8ETR. It is always set to
|
||
0.
|
||
|
||
Programs requiring frequent changes in and out of image mode on a TTY
|
||
line do not always get processed correctly.
|
||
|
||
|
||
|
||
4.0 INSTALLATION INSTRUCTIONS
|
||
|
||
The installation instructions are found in the DECsystem-10 Software
|
||
Notebooks Installation Guide and in the DN92.SIG file on the
|
||
distribution tape.
|
||
|
||
|
||
|
||
5.0 INTERNAL CHANGES
|
||
|
||
The DN92 was sending a NAK response for an idle REP. It now sends an
|
||
ACK response. The routine which ships status words to the host only
|
||
sends it if it has changed values. Instead of halting, the DN92 now
|
||
ignores a REQUEST LOAD station control message.
|
||
|
||
|
||
|
||
6.0 SUGGESTIONS
|
||
|
||
Be sure to read the Network Software Installation Guide before
|
||
installing the system software. Also be sure to set up the NETLDR.INI
|
||
file correctly if there are multiple DN92'S in the network.
|
||
|
||
|
||
|
||
[End of DN9210.DOC]
|