mirror of
https://github.com/antonblanchard/microwatt.git
synced 2026-01-13 15:18:09 +00:00
Recognize version string "0.12" in recent OpenOCD master
Starting from 5e7612eb4, OpenOCD identifies itself as 0.12. This causes Microwatt's flash-arty script to fail. Because neither the cfg nor the proxy bitstream are affected, we can keep treating everything as indistinguishable from 0.11. This patch simply tests for "0.12" as an alias; it would probably be better to replace this confusing terminology with something like "single-tap/multi-tap". Signed-off-by: Boris Shingarov <shingarov@labware.com>
This commit is contained in:
parent
d3fb2639dd
commit
ed5807381e
@ -27,6 +27,8 @@ def get_version():
|
||||
return ""
|
||||
if a.stderr.count(b"0.11"):
|
||||
return "_openocd_v0.11"
|
||||
if a.stderr.count(b"0.12"):
|
||||
return "_openocd_v0.11"
|
||||
|
||||
parser = argparse.ArgumentParser()
|
||||
parser.add_argument("file", help="file to write to flash")
|
||||
|
||||
Loading…