HISTORY.DOC Summary PC/370 Release History
|
||
|
||
MMS/370 R1.0 12/28/81 first beta test demo for Z80 CP/M-80
|
||
|
||
Successful demo program assembly, link, and execute
|
||
completed on the following systems:
|
||
|
||
1. Radio Shack Model II with Lifeboat CP/M v2.2.
|
||
2. Cromemco system with Tarbell CP/M v1.4.
|
||
|
||
MMS/370 R1.1 01/04/82 first Distributor evaluation version
|
||
sent to Lifeboat Assoc. for evaluation
|
||
|
||
MMS/370 R1.2 12/20/82 second beta test
|
||
|
||
MMS/370 R1.3 02/12/83 first user release
|
||
|
||
A370
|
||
1. Add XREAD, XPRNT, XDECI, XDECO, XFILI, XFILO, XDUMP
|
||
2. Fix location 0 overlay processing missing END.
|
||
3. Force E22 length error for 0 length program.
|
||
L370
|
||
1. Force E08 memory error for 0 length segment.
|
||
2. Fix incorrect SEARCH return code due to DEQ.
|
||
3. Fix ORG error at end if no literals.
|
||
4. Fix bad stack address at program entry with option G.
|
||
5. Fix object code error when control Z is first byte of
|
||
physical block in concatenated object file.
|
||
6. Allow alternate disk drive A for L370.LIB if not found
|
||
on specified drive for object file.
|
||
E370
|
||
1. Add ASSIST support plus interactive debug log option.
|
||
2. Add 370 instruction trace and instruction address stop.
|
||
3. Add 370 address protection for CP/M and E370 areas.
|
||
|
||
MMS/370 R2.2 05/04/83 second user release with new XA extensions
|
||
|
||
A370
|
||
1. 27 new instructions added including BAS, BASR, MVCIN,
|
||
BSM, and BASSM.
|
||
2. Fix made to handle explicit 256 byte SS instructions
|
||
correctly.
|
||
3. Fix DC logic to surpress duplicate references to *.
|
||
4. FIX SVC interface to save IX and IY for NEC PC MSDOS.
|
||
L370
|
||
1. Fix stack pointer for execution for option G to prevent
|
||
initial call from storing address in program area. Also
|
||
changed call in prefix to simple jump to emulator entry.
|
||
E370
|
||
1. 5 new non-privileged instructions supported along with
|
||
PSW address mode bit 17.
|
||
2. The existing instructions LA, BAL, BALR, EDMK, and TRT
|
||
all have been modified to function correctly in both
|
||
24 and 31 bit addressing modes.
|
||
3. Fix incorrect instruction length code in BAL 24 bit
|
||
mode .
|
||
4. Fix incorrect EDMK address for single byte PD fields.
|
||
5. Fix incorrect SS instruction processing when length is
|
||
over 128.
|
||
6. Fix fixed point multiply and divided overflow when
|
||
result is negative.
|
||
7. Fix sign of remainder for fixed and packed divide.
|
||
8. Fix packed decimal compare for negative zero.
|
||
9. Fix condition codes for multiply and divide exceptions.
|
||
10. Fix Assist XREAD to correctly support 1 byte area.
|
||
11. Fix arithmetic shift left overflow logic.
|
||
12. Fix packed decimal divide to correctly detect overflow.
|
||
|
||
MMS/370 R2.3 06/30/83 third user release with updated XA
|
||
extensions
|
||
|
||
A370
|
||
1. Add IPM and other new XA supervisor instructions
|
||
L370
|
||
E370
|
||
1. Add IPM instruction
|
||
2. Change XA mode PSW bit to 32 and display extended mode PSW
|
||
when in XA mode.
|
||
3. Correct BSM logic to skip save when first register is 0.
|
||
4. Add option to update 370 registers to MMDBUG command Y.
|
||
5. Reduce size of E370 by 500 bytes by changing logic macros
|
||
to common subroutines for logical RR and RX instructions.
|
||
|
||
MMS/370 R3.1 03/08/84 maintenance release with corrections
|
||
|
||
A370
|
||
1. Fix error created by V type address constant referencing
|
||
CSECT defined later in same assembly.
|
||
2. Fix length attribute of CSECT/DSECT to always be 1.
|
||
L370
|
||
E370
|
||
1. Fix error in XR and X exclusive OR logic introduced in R2.3
|
||
when logic was combined in 1 routine to save memory.
|
||
2. Fix DP overflow logic to cause divide exception 0CB instead
|
||
of divide overflow. Note divide exception cannot be masked
|
||
like overflow but SPIE can be used to handle it.
|
||
3. Check for interrupt every 256 instructions even in kill
|
||
mode.
|
||
4. Only trace IFL entries in 370 mode for N command.
|
||
5. Fix NODBUG minimum storage replacement module for MMDBUG to
|
||
correctly NOP 370 TRACE calls.
|
||
|
||
PC/370 R1.0 06/08/85 first freeware release for 8086 MSDOS systems
|
||
|
||
A370
|
||
L370
|
||
1. Force option F to always dynamically load E370.EXE. The
|
||
emulator can no longer be linked with 370 code since L370
|
||
does not process native 8086 assembler object code format.
|
||
E370
|
||
1. Add SVC's 17-22 to handle extended MSDOS functions such as
|
||
time.
|
||
|
||
PC/370 R1.1 11/11/85 maintenance release
|
||
|
||
A370
|
||
1. Allow lower case command line.
|
||
2. Fix error for zero length data in DC for alignment.
|
||
L370
|
||
1. Allow lower case command line.
|
||
E370
|
||
1. Allow lower case debug command entry.
|
||
2. Initialize register 13 to standard save area.
|
||
3. Support 370 instruction address reset via J command.
|
||
4. Only stop at IFL trace in 370 address stop mode.
|
||
5. Attempt to close all files when exiting via <esc> command.
|
||
DOC
|
||
1. Add documentation files describing trace id points.
|
||
|
||
PC/370 R1.2 07/18/86 maintenance release plus SEE editor utility
|
||
|
||
A370
|
||
1. Drop form feed on first page heading.
|
||
2. Translate lower case ASCII comments to upper case.
|
||
3. Align column headings for cross reference and repeat
|
||
headings.
|
||
4. Fix error when DC F coded without data - now issues error.
|
||
5. Rearrange opening of files in pass 2 to insure that no more
|
||
memory is required in pass 2 than in pass 1. This allows
|
||
number of symbols to directly determine maximum assembly
|
||
possible (SEE is within 30 symbols of maximum now). Note
|
||
debug was removed from A370 (8k) to provide more symbol
|
||
space. Also note in pass 2, ALC file buffer will be smaller
|
||
to provide room for object and print file buffers if
|
||
necessary to not exceed pass 1 memory usage.
|
||
6. Tighten TITLE syntax to require correct leading quote.
|
||
L370
|
||
1. Drop form feed on first page heading.
|
||
2. Align column headings with data lines.
|
||
3. Correct bug causing CSECT reference labels to be truncated.
|
||
E370
|
||
1. Correct bug in XDECI ASSIST instruction to correctly input
|
||
negative numbers.
|
||
2. Translate DDNAME to ASCII for SEARCH and DELETE SVC's.
|
||
3. Reverse DMAS, DMAE, BLKE addresses during OPEN/CLOSE along
|
||
with EODAD and SYNAD addresses to support user defined
|
||
buffer.
|
||
4. Change debug trace to only trace first ID after IFL in 370
|
||
mode.
|
||
5. Support trace ID's IOF and ION to turn interrupts off and
|
||
on.
|
||
6. Fix bug in IOS get text record routine which caused
|
||
premature end of file when DCB was within 128 bytes of
|
||
buffer area due to uninitialized register picking up DCB
|
||
address instead of DMA address during pending EOF
|
||
processing.
|
||
7. Fix bug in IOS random write routine to increment block
|
||
pointer when writing blocks larger than 128 bytes.
|
||
8. Change debug to not kill SVC 9 trace entries from 370 code.
|
||
9. Add SVC 23 to perform RENAME using DCB with EBCDIC names.
|
||
(See SEE.ALC for example use and IHADCB extensions.)
|
||
10. Add SVC 24 to microcode printing line of ASCII text on
|
||
screen with attribute colors. (used to more than double SEE
|
||
speed).
|
||
11. Fix memory management to not allocate from last FQE unless
|
||
there is room for a remaining smaller FQE pointer. Force
|
||
end of memory at x'FF00' to leave room for stack.
|
||
12. Support S save/unsave debug command to protect current trace
|
||
ID while running in kill mode. (very useful to obtain high
|
||
speed execution up to selected point in program).
|
||
13. Save 8086 flags in high R0 for BIOS SVC's such as KEYBOARD.
|
||
14. Add explicit EBCDIC/ASCII translation and line control
|
||
options to SVC's 0-24 via high bits of R2:
|
||
bit 0 - explicit control if on, else use option E
|
||
bit 1 - force EBCDIC translation if on, else use ASCII
|
||
bit 2 - force addition of line control, else none
|
||
|
||
(For example ICM R2,8,=X'80' would force no translation
|
||
and no line control regardless of option E setting.)
|
||
15. Fix debug N trace listing to translate SVC 9 EBCDIC Id's.
|
||
|
||
DOC
|
||
1. Add SEE.ALC source code utility to edit or browse an ASCII
|
||
text file in full screen color mode. Keystrokes are
|
||
compatible with Turbo Pascal and PFS:WRITE. The editor
|
||
supports files up to 512k. SEE includes character graphics
|
||
to support line drawings and organizational chart drawings.
|
||
SEE also supports creation of session keystroke file (.KSF)
|
||
which can be reused to recreate SEE session with full screen
|
||
colors and with keyboard pause and wait control.
|
||
2. Add PRINT.ALC source code utility to print source programs
|
||
and PC370.DOC documentation file with page control.
|
||
3. Add information on electronic bulletin board and PC-SIG
|
||
distribution via disk #402.
|
||
4. Add DW3NUM.ALC source code utility to insert line numbers on
|
||
all non-blank lines in a Displaywrite III text document.
|
||
Numbers are placed in left margin and reset at beginning of
|
||
each page. This program serves as a model for other
|
||
utilities that could be written to process Displaywrite III
|
||
document files directly. This utility squeezes file and
|
||
lists file on console in the process of inserting line
|
||
numbers.
|
||
5. Drop form feed on first page heading for PRINTDOC.ALC.
|
||
|
||
PC/370 R2.0 05/16/87 major update with 512 address space support
|
||
|
||
A370
|
||
1. Converted to EXE format with 64k data segment and buffer
|
||
segment.
|
||
2. Now supports 3 times as many labels and literals.
|
||
3. File handle I/O with pathing much more efficient.
|
||
4. Fix error if DSECT's contain anything but DS instructions.
|
||
5. Allow references to ENTRY symbols within same module.
|
||
L370
|
||
1. Converted to EXE format with 64k data segment and buffers
|
||
segment.
|
||
2. Now supports code modules up to 50k.
|
||
3. File handle I/O with pathing much more efficient.
|
||
4. New option M creates 370 MOD file without COM prefix.
|
||
E370
|
||
1. Converted to EXE format running in high 64k segment.
|
||
2. The standard instruction set plus ASSIST now supports
|
||
direct addressing up to the maximum available memory
|
||
under MS-DOS 2.0+ (512k+).
|
||
3. Error in one byte overlapped pack instruction corrected.
|
||
4. Error in BXH and BXLE with negative updated index values
|
||
fixed.
|
||
5. Memory management now supports the full address space
|
||
using 8 byte free queue elements (4 byte address and
|
||
4 byte length). ASCASF FQE chain pointer is located at
|
||
X'118'in new address space control block. The same
|
||
registers for SVC 10 and 11 are used.
|
||
6. File management support has been rewritten using MS-DOS
|
||
file handle I/O to support pathing and random or
|
||
sequential access to multiple files. Each file can
|
||
have up to 64K buffer. Maximum files open is
|
||
controlled by CONFIG.SYS FILES= parameter. See
|
||
DOC\SYSTEM.DOC and CPY\IHADCB.CPY for more information.
|
||
7. The interactive debug facility has been expanded to
|
||
provide additional support for virtual address space
|
||
separate from emulator address space. The Z command
|
||
determines which address space functions refer to. The
|
||
debug facility is included in A370 and L370 as well as
|
||
E370. A new "I" command added, dumps full word counter
|
||
which is source record count in A370, logical object record
|
||
in L370, and 370 instruction counter in E370. Address stop
|
||
on this word can be used to stop execution at any desired
|
||
point. However, note that in kill mode, the counter may be
|
||
incremented more than once between trace ids preventing
|
||
address stop on equal from triggering.
|
||
8. The interface between linked COM modules and the E370.EXE
|
||
emulator has been redesigned to use the MS-DOS standard EXEC
|
||
function instead of somewhat non-standard overlay load. Now
|
||
the first 16 bytes of each linked COM module contains the
|
||
EXEC mainline which links to E370.EXE in the high 64k of
|
||
available memory. E370.EXE initializes the virtual address
|
||
space origin 16 bytes past the beginning of the COM module
|
||
with executable code starting at X'210' into module or
|
||
relative X'200'. COM mainline will abort if there is not
|
||
room for COM module plus 64k for E370.EXE.
|
||
9. E370.EXE now supports SVC 25 to load any kind of file
|
||
including linked COM files into free memory. See
|
||
DOC\SYSTEM.DOC and CPY\IHASCB.CPY.
|
||
10. E370.EXE now supports SVC 26 an 27 for attach and detach of
|
||
COM 370 programs which run in their own relative address
|
||
spaces. See DEMO\DEMOPSW series of demo programs for
|
||
example.
|
||
11. Fix trace and PSW address of EX target instructions.
|
||
|
||
PC/370 R2.0A 05/24/87 fixes to 2.0
|
||
|
||
A370
|
||
1. EQU's preceeding first CSECT caused 0 length blank CSECT
|
||
error.
|
||
L370
|
||
E370
|
||
1. Error in Freemain svc 11 when releasing block between two
|
||
existing free blocks chained to third free block.
|
||
2. I/O supervisor now takes SYNAD exit if bad RBA causes random
|
||
read or write to fail due to pointing beyond disk capacity.
|
||
|
||
PC/370 R3.0 08/30/87 new macro preprocessor, floating point,
|
||
scientific subroutines, generic interrupt SVC, ASCII string
|
||
constants, MVS shell demo with SIO channel simulator
|
||
A370
|
||
1. Support for E, D, and L floating point constants added.
|
||
2. ASCII string constants in double quotes added and self
|
||
defining string constants fixed to handle C'''' etc.
|
||
3. Error in DS or DC destroyed location counter causing
|
||
additional erroneous base errors in following instructions.
|
||
4. Treat blank lines like comments instead of syntax errors.
|
||
L370
|
||
1. Error in concatenating object files when previous file ends
|
||
exactly on 128 block boundary.
|
||
2. Add option I to surpress all interrupts during execution.
|
||
3. Add option P to surpress floating point even if 80x87 avail.
|
||
E370
|
||
1. Floating point instructions added using 80x87.
|
||
2. SVC's 28-35 added to assist use of ASCII strings, generic
|
||
interrupt to issue any MS-DOS or BIOS interrupt with user
|
||
defined PC registers, plus scientific subroutine assist
|
||
using 80x87 routines for square root, 2**X, tangent,
|
||
arctangent, logs.
|
||
3. Fixed ASCII file output translation option (was translating
|
||
after write) in PUT svc.
|
||
4. Correct ASCII/EBCDIC translation of left bracket and GE
|
||
symbols.
|
||
5. Correct debug jump command to handle addresses over 64k in
|
||
370 mode.
|
||
6. Correct MP to return specification error if L'A LE L'B, L'B
|
||
GT 8, or high bytes of A for length L'B not zero.
|
||
|
||
PC/370 R3.1 09/02/87 maintenance to R3.0 based on user feedback
|
||
|
||
A370
|
||
1. Fix error in object code ORG when DS is used in multiple
|
||
CSECT module causing L370 link error due to ORG exceeding
|
||
length of CSECT (offset to start of non-zero CSECT was not
|
||
being subtracted to calculate relative CSECT ORG address).
|
||
Explicit ORG's worked fine, only a DS generated ORG caused
|
||
error.
|
||
L370
|
||
E370
|
||
|
||
PC/370 R3.2 09/07/87 maintenance to R3.1 based on user feedback
|
||
|
||
A370
|
||
1. Allow maximum 80 character ALC source with seq. #.
|
||
2. Fix label equated to CSECT/DSECT which caused L370 errors.
|
||
3. Flag DC error for RLD's for DSECT labels which caused L370
|
||
errors.
|
||
L370
|
||
E370
|
||
1. Fix ZAP to correct regression bug with R2.0 where any number
|
||
with zero in low nibble gives positive sign and zero
|
||
condition.
|
||
|
||
PC/370 R4.0 11/08/87 maintenance to R3.1 based on user feedback
|
||
|
||
A370
|
||
1. Add support for COPY statement to include source code from
|
||
any MS-DOS path\filename. The default suffix is CPY.
|
||
L370
|
||
1. Add option B to create file identical to COM file but with
|
||
suffix BIN for use with Micro Focus COBOL.
|
||
E370
|
||
1. Support resident option invoked by directly executing the
|
||
emulator EXE module.
|
||
2. Support calls from Micro Focus COBOL in resident mode using
|
||
standard linkage conventions and V=R addressing mode.
|
||
3. Modify OPEN logic to allow use of SYNAD exit even though
|
||
file may not be open due to error such as file not found.
|
||
Add error and function codes in R0 and R1 for use by SYNAD
|
||
exit in determining error (see LIB\SYNERROR.ALC).
|
||
|
||
PC/370 R4.1 11/20/87 maintenance to R4.0 based on user feedback
|
||
|
||
A370
|
||
1. Correct ORG to correctly handle CSECT or DSECT name as well
|
||
as any relative expression (The code was only allowing
|
||
relative expression operand rather than special label type).
|
||
L370
|
||
|
||
E370
|
||
1. Correct serious bug in release 4.0 which stores 8 byte free
|
||
queue element directly after the end of each BIN module.
|
||
(This code to build free area behind COM modules can cause
|
||
COBOL run time system to crash after exiting from
|
||
subroutine depending on use of area overlayed).
|
||
2. Add optional parameter to define size of system queue area
|
||
(SQA) memory in the resident emulator address space for use
|
||
by COBOL subroutines. Size is in hex paragraphs and default
|
||
is 10 or 256 bytes. Through use of SQA, COBOL subroutines
|
||
can now perform standard file I/O with dynamic buffer
|
||
allocation (See BAT\RUNCBL.BAT demo for example SQA and
|
||
I/O use).
|
||
3. Enhance interactive debug to support resident reusability by
|
||
restoring all traces at beginning of each COM execution and
|
||
at beginning of all COBOL subroutines called with option D
|
||
specified at link edit. Also toggle command K can be used
|
||
to restore traces at any point in program execution (This
|
||
allows quickly reaching a selected point in program and then
|
||
restoring traces for complete instruction tracing).
|
||
3. Support user defined standard COBOL return code using value
|
||
in register 15 (low 16 bits) at exit.
|
||
|
||
PC/370 R4.2 01/05/88 Micro Focus XM protected mode support
|
||
|
||
A370
|
||
L370
|
||
1. Add option U to allow undefined external references.
|
||
E370
|
||
1. Support Micro Focus XM COBOL protected mode call to PC/370
|
||
assembler subroutine in BIN file (See USER.DOC for more).
|
||
The resident interrupt was moved from hex DC to hex 60.
|
||
(See PTF.DOC for fix to change interrupt # if it conflicts.)
|
||
2. Fix 0C9 on CVB with negative zero packed decimal input.
|
||
3. Correct EBCDIC to ASCII translate tables to handle
|
||
> { and [ conversion in both directions (half fixed in 3.0).
|
||
4. Flag error for text file with LRECL<2.
|
||
5. Fix SRP to use only low 6 bits in second operand for shift.
|
||
(If the 6 bit number was positive, 8 bits were used.)
|
||
6. MVS standard parm list with address, half word count, and
|
||
EBCDIC parm field is now pointed to by R1 at entry.
|
||
7. If floating point option is on and 80X87 is installed,
|
||
hardware assist is used for CVB and CVD to speed up
|
||
instruction by up to 4 times for large numbers.
|
||
8. Add MVS program interruption element (PIE) control block
|
||
pointed to by R2 at entry to SPIE trap. This allows full
|
||
recovery from trap without losing content of registers.
|
||
(See CPY\IHAPIE.CPY for more information.)
|
||
9. Fix incorrect PSW on exception of executed instruction.
|
||
10. Add SVC 36 to load overlay file at specified virtual
|
||
address.
|
||
11. Add SVC 37 to define SVC user exit table.
|
||
See DEMO\DEMOTRAP.ALC for examples.
|
||
12. Add production version of emulator E370P42.EXE without
|
||
interactive debug or ASSIST facility to save 10k.
|
||
|