USER.DOC PC/370 User Documentation
|
||
|
||
Copyright 1987 Donald S. Higgins
|
||
|
||
Don Higgins
|
||
6365 - 32 Avenue North
|
||
St. Petersburg, Florida 33710
|
||
|
||
E-mail CompuServe 73047,1113
|
||
|
||
PC/370 users:
|
||
|
||
This is the user documentation for the PC/370 cross assembler,
|
||
linkage editor, and emulator for 370 assembly language users.
|
||
The PC/370 package provides the capability to assemble, link,
|
||
and execute IBM 370 assembler programs on any 80x86 MSDOS 2.0+ micro
|
||
computer such as the IBM PC, XT, AT, PS/2, Compaq, etc.
|
||
|
||
Chapter table of contents:
|
||
|
||
1. M370.COM macro preprocessor
|
||
|
||
2. A370.EXE cross 370 assembler
|
||
|
||
3. L370.EXE cross 370 linkage editor
|
||
|
||
4. E370R42.EXE run time 370 emulator
|
||
|
||
5. Technical hardware and software specifications
|
||
|
||
6. ASSIST extended instructions for student use
|
||
|
||
7. DEBUG interactive debugging facility
|
||
|
||
8. Floating point instructions and scientific subroutines
|
||
|
||
9. XA extended architecture instructions
|
||
|
||
10. System subroutine library
|
||
|
||
11. COBOL call interface
|
||
|
||
12. Reference publications
|
||
|
||
*********
|
||
|
||
Chapter 1. M370.COM macro preprocessor
|
||
|
||
*********
|
||
|
||
The M370 macro preprocessor has the following command format:
|
||
|
||
A>M370 file
|
||
|
||
where file is the name of a source macro program file which has the
|
||
suffix (.MLC). The source file must be in ASCII text format with
|
||
each line terminated by a line feed character. The only output from
|
||
this program is a source basic assembler file with expanded macro
|
||
statements. The suffix of the output file is (.ALC).
|
||
|
||
Any number of macros can be used by M370 input files and must be
|
||
defined in individual source macro files with the file name equal to
|
||
the macro name and a suffix of (.MAC). These macros must be placed on
|
||
the default drive for access by M370. For more speed, these files may
|
||
be moved to RAM disk.
|
||
|
||
*********
|
||
|
||
Chapter 2. A370.EXE cross 370 assembler
|
||
|
||
*********
|
||
|
||
The A370 assembler has the following command format:
|
||
|
||
A>A370 file/options
|
||
|
||
where file is the name of a source program file which has the
|
||
suffix (.ALC). The source file must be in ASCII text
|
||
format with each line terminated by a line feed character.
|
||
Any number of editors including SEE can be used to create ALC files.
|
||
An optional drive and path may be specified such as B:\dir\file.
|
||
The options which can be specified are as follows:
|
||
|
||
A - alignment option. Default is on.
|
||
C - object code option. Default is on.
|
||
L - produce listing file (.PRN). Default is none.
|
||
T - trace assembler execution. Default is off.
|
||
X - produce symbol and literal cross reference. Default is none.
|
||
|
||
If an option is on by default, specifying it will turn it off.
|
||
For example:
|
||
|
||
A>A370 B:DEMOPNUM/LX
|
||
|
||
will read the source file B:DEMOPNUM.ALC and produce the object
|
||
code file B:DEMOPNUM.OBJ and the listing file B:DEMOPNUM.PRN.
|
||
|
||
The A370 assembler conforms to the OS/VS IBM 370 Assembly
|
||
Language as defined in the IBM manual GC33-4010 with the
|
||
following limitations:
|
||
|
||
1. No continuation lines.
|
||
2. Maximum control sections and dummy sections is 255.
|
||
3. Macros and system variable symbols are not supported (see M370).
|
||
4. OPSYN statement not supported.
|
||
5. EQU third operand (type attribute) not supported.
|
||
6. Scale, exponent, and bit length data modifiers not supported.
|
||
|
||
Extended features include the following:
|
||
|
||
1. Data constant types F and H may use arithmetic expressions.
|
||
|
||
2. Extended ASSIST instruction set including XREAD, XPRNT,
|
||
XDECI, XDECO, AND XDUMP as defined in the book Assembler
|
||
Language with ASSIST by Ross A. Overbeek. Also 2 more
|
||
instructions XFILI and XFILO are added to allow changing
|
||
default ASSIST input and output files at execution time.
|
||
|
||
3. ASCII character strings may be defining by using double
|
||
quotes instead of single quotes in DC and self defining
|
||
character constants.
|
||
|
||
*********
|
||
|
||
Chapter 3. L370.EXE cross 370 linage editor
|
||
|
||
*********
|
||
|
||
The L370 linkage editor has the following command format:
|
||
|
||
A>L370 file/options
|
||
|
||
where file is the name of an A370 object code file (.OBJ) and
|
||
may specify a specific drive. The options supported by the
|
||
linkage editor are as follows:
|
||
|
||
B - create VS COBOL callable subroutine file (type .BIN).
|
||
D - set debug mode for emulator. Default is off. When option D
|
||
is on, interactive debug is entered at beginning of each
|
||
COM or BIN file execution.
|
||
G - load and execute with no file output. Default is off.
|
||
I - turn off all interrupts from keyboard.
|
||
L - list CSECT addresses and lengths. Default is off.
|
||
M - create 370 code module without COM prefix code.
|
||
O - dump input object code records in hex. Default is off.
|
||
P - force floating point option off even if 80x87 installed.
|
||
X - cross reference of external symbols. Default is off.
|
||
U - allow unresolved external references
|
||
|
||
For example:
|
||
|
||
A>L370 B:DEMOPNUM/LX
|
||
|
||
will read the object code file B:DEMOPNUM.OBJ and produce the binary
|
||
command file B:DEMOPNUM.COM, and the listing and cross-reference file
|
||
B:DEMOPNUM.LST. Note that since DEMOPNUM calls the external
|
||
subroutine PET, the subroutine library L370.LIB must be available.
|
||
The binary command file B:DEMOPNUM.COM may be directly executed by the
|
||
MSDOS command:
|
||
|
||
A>B:DEMOPNUM
|
||
|
||
When the above command is executed, the program will load at X'0200'
|
||
and the fetch routine linked with the program will load the
|
||
emulator E370.EXE in high memory and transfer control to it.
|
||
|
||
The linkage editor uses two concatenated subroutine library
|
||
files. The first file is named file.LIB and may contain
|
||
any number of A370 subroutine object modules which are called by the
|
||
modules in file.obj. This file is optional and only called modules
|
||
are included. The second file is named L370.LIB and may contain any
|
||
number of A370 subroutine object modules which are commonly used by
|
||
multiple programs. An L370.OBJ file is included with the PC/370
|
||
package and contains sample time and date routines. The MS-DOS COPY
|
||
command with option /B may be used to concatenate A370 object modules
|
||
in either library file. Note module references must be resolved in
|
||
one sequential pass of library so backward module references may cause
|
||
unresolved entry.
|
||
|
||
The linkage editor listing file (.LST) shows relative entry point
|
||
and segment lengths and optional cross reference by segment. The
|
||
last line of the listing contains ENT/LNG which is the 370 relative
|
||
entry point of the module and the length of the entire module.
|
||
|
||
*********
|
||
|
||
Chapter 4. E370R42.EXE run time 370 native machine code emulator
|
||
|
||
*********
|
||
|
||
The emulator is transparent to the user when using A370 and L370 to
|
||
create MSDOS command files. The emulator is dynamically executed by
|
||
the 80x86 COM file prefix generated by L370. The 370 machine code
|
||
starts at X'210' from the beginning of the COM file. The origin of
|
||
the 370 virtual address space for a COM program starts at X'10' from
|
||
the beginning of the COM file. The execution of the 370 machine code
|
||
will start at the specified relative start address plus hex 200 with
|
||
that absolute address in register 15. Register 1 will point to
|
||
standard MVS parameter list address at location X'80' with EBCDIC text
|
||
passed from MS-DOS command line. Register 13 will point to standard
|
||
save area in ASCB and register 14 points to return to detach
|
||
instruction in ASCB to exit to MS-DOS. If a program check occurs, the
|
||
interactive debug facility will be invoked and will initially display
|
||
the general registers and the program status word at the time of the
|
||
interruption. See DOC\SYSTEM.DOC SPIE supervisor call for facility to
|
||
handle program checks. Also see MAC\MVS.MLC for example of how to run
|
||
programs in problem state with your own supervisor shell.
|
||
|
||
A new facility with PC/370 release 4 is the ability to make the
|
||
emulator resident by simply executing it directly. The resident
|
||
emulator reserves about 50k for code and uses an 80x86 hardware
|
||
interrupt to transfer control when needed at execution time. To
|
||
remove the current resident emulator, simply execute it directly
|
||
again. Release 4.0 and 4.1 used interrupt hex DC. Release 4.2 uses
|
||
hex 60 within the Micro Focus Extended Memory (XM) real interrupt
|
||
handler range of hex 60-6F. See DOC\PTF.DOC for pathc to change
|
||
interrupt in case it conflicts with another user installed software
|
||
package.
|
||
|
||
With release 4.1 a new system queue area (SQA) memory option has been
|
||
added to define a memory which can be shared by all COBOL subroutines
|
||
and which is allocated in the resident emulator address space. The
|
||
size of the SQA is specified by a single hex parm when making the
|
||
emulator resident. The size is in hex paragraphs and the default is
|
||
10 or 256 bytes. For example, the following command would make the
|
||
emulator resident with an 8k byte SQA:
|
||
|
||
C>E370R42 200
|
||
|
||
With the SQA facility, COBOL assembler subroutines can issue standard
|
||
file I/O with dynamic buffers allocate from SQA. See BAT\RUNCBL.BAT
|
||
for demo.
|
||
|
||
With release 4.2, PC/370 supports Micro Focus COBOL/2 assembler
|
||
subroutine calles in normal MS-DOS mode or in extended memory XM mode.
|
||
In both cases the emulator must be resident before starting the COBOL
|
||
program via workbench or run time executive with or without XM. In
|
||
XM mode, the emulator still runs in real mode after requesting XM to
|
||
mode the called subroutine code (BIN file) and the argument data
|
||
segments to base memory area for access in V=R real mode. This
|
||
creates the XM restriction that there must be sufficient base memory
|
||
for called BIN file and data segment at the time of the call. Also,
|
||
the emulator must not attempt to access memory beyond end of BIN or
|
||
data segments in real memory. The emulator can use SQA in XM mode.
|
||
See BAT\RUNCBL.BAT for demo of XM mode subroutines (requires XM.EXE
|
||
and RUN.EXE from Micro Focus).
|
||
|
||
There are five distinctly different ways to execute the E370 emulator:
|
||
|
||
1. Direct execution to make it resident if not currently resident.
|
||
|
||
2. Direct execution again to remove current resident copy. If
|
||
another software package is using interrupt, an error message
|
||
will display. See DOC\PTF.DOC to change interrupt number.
|
||
|
||
3. Execution of a 370 COM module without E370 resident causes
|
||
dynamic loading of E370 in high 64k of MS-DOS memory to support
|
||
execution of 370 code in the COM module.
|
||
|
||
4. Execution of a 370 COM module with E370 module resident causes
|
||
execution of resident copy via cross memory interrupt facility.
|
||
|
||
5. Execution of a 370 BIN module from within Micro Focus COBOL run
|
||
time environment causes execution of resident copy via cross
|
||
memory interrupt facility. In XM mode, a protected interface
|
||
routine in the emulator is called directly by the BIN module
|
||
which in turn issues interrupt to execute emulator in real mode.
|
||
|
||
|
||
*********
|
||
|
||
Chapter 5. Technical specifications
|
||
|
||
*********
|
||
|
||
1. A370.EXE requires 256k memory to execute and can handle source
|
||
programs with over 1000 labels.
|
||
|
||
2. L370.EXE requires 256k memory and can handle load modules up to
|
||
50k bytes long.
|
||
|
||
3. E370R42.EXE requires 50k plus SQA which includes the emulator,
|
||
and the extended SVC support functions, and interactive debug.
|
||
A production only copy of the emulator named E370P42.EXE is
|
||
included which only requires 40k but does not include
|
||
interactive debug facility or the ASSIST extended instructions.
|
||
This version saves resident base memory, but should only be
|
||
used for fully tested programs or programs with their own
|
||
program check handlers for error recovery.
|
||
|
||
4. E370R42 supports all the non-supervisor state IBM 370
|
||
instructions as defined in the IBM/370 XA Principals
|
||
of Operation manual SA22-7085 except the conditional
|
||
swapping feature instructions. Short, long, and extended
|
||
floating point instructions are supported provided 80x87
|
||
is installed.
|
||
|
||
5. The minimum configuration for PC/370 is as follows:
|
||
a. 80x86 processor. XM only supported on 80286/80386.
|
||
b. 256k RAM memory which allows execution of 370 program in
|
||
128k virtual address space. Maximum virtual address space
|
||
is about 512k on 640k machine.
|
||
c. 1 floppy disk drive.
|
||
d. 80x87 only required for floating point instructions.
|
||
|
||
6. A benchmark program consisting of calculating the first
|
||
100 prime numbers was run in interpretive BASIC using
|
||
16 bit integer arithmetic. It took 67 seconds on a
|
||
4.77 MHZ 8086 system. The same program was rewritten in
|
||
370 assembler using 32 bit fixed point arithmetic. It
|
||
took 25 seconds to execute on the same system. This
|
||
benchmark program is included as a demo called DEMOPNUM.ALC.
|
||
|
||
The demo may be run with the following commands:
|
||
|
||
A>A370 DEMO\DEMOPNUM/LX (create DEMOPNUM.OBJ)
|
||
A>L370 DEMO\DEMOPNUM/LX (create DEMOPNUM.COM)
|
||
A>DEMO\DEMOPNUM
|
||
|
||
7. The following error messages are supported:
|
||
|
||
A370/L370
|
||
|
||
E01 - DUPLICATE LABEL
|
||
E02 - INVALID LABEL
|
||
E03 - SYMBOL TABLE FULL
|
||
E04 - INVALID OPERATION CODE
|
||
E05 - UNDEFINED OPERATION CODE
|
||
E06 - UNDEFINED LABEL
|
||
E07 - INVALID OPERAND
|
||
E08 - MEMORY FULL
|
||
E09 - EXPRESSION INVALID
|
||
E10 - SELF DEFINING TERM INVALID
|
||
E11 - ARITHMETIC OVERFLOW IN EXPRESSION
|
||
E12 - TOO MANY EXTERNAL SYMBOLS
|
||
E13 - NO BASE REGISTER AVAILABLE
|
||
E14 - LENGTH ERROR
|
||
E15 - OPERAND ERROR
|
||
E16 - DATA CONSTANT DUPLICATION FACTOR ERROR
|
||
E17 - DATA CONSTANT TYPE ERROR
|
||
E18 - DATA CONSTANT LENGTH ERROR
|
||
E19 - DATA CONSTANT DATA ERROR
|
||
E20 - START SEQUENCE ERROR
|
||
E21 - LTORG SEQUENCE ERROR
|
||
E22 - LOCATION COUNTER ERROR BETWEEN PASS 1 AND 2
|
||
|
||
8. IOS LOGICAL ACCESS METHOD USED BY A370, L370, AND E370
|
||
|
||
IOS001 - NO DISK SPACE
|
||
IOS001 - FILE NOT FOUND
|
||
IOS001 - NO BUFFER SPACE
|
||
IOS001 - OPEN FAILED
|
||
IOS002 - CLOSE FAILED
|
||
IOS003 - READING UNWRITTEN DATA
|
||
IOS003 - INVALID REQUEST
|
||
IOS004 - ERROR IN EXTENDING FILE
|
||
IOS004 - END OF DISK DATA AREA
|
||
IOS004 - NO MORE DIRECTORY SPACE
|
||
IOS004 - INVALID REQUEST
|
||
IOS005 - INVALID RECORD TYPE
|
||
IOS005 - INVALID RECORD LENGTH
|
||
IOS006 - INVALID RECORD TYPE
|
||
IOS006 - INVALID RECORD LENGTH
|
||
IOS007 - DELETE FAILED
|
||
|
||
*********
|
||
|
||
Chapter 6. ASSIST extended instructions for student use
|
||
|
||
*********
|
||
|
||
A. Overview
|
||
|
||
The book, "Assembler Language With ASSIST", by Ross A. Overbeek
|
||
and W. E. Singletary published by Science Research Associates,
|
||
Inc. in 1976 describes a set of 370 extended instructions to
|
||
greatly simplify input and output for students learning to write
|
||
370 assembler programs. A new book with also covers ASSIST is,
|
||
"IBM 370 Assembly Language with ASSIST, Structured Concepts, and
|
||
Advanced Topics", Charles J. Kacmar, Prentice Hall, September
|
||
1987, ISBN 0-13-455742-5.
|
||
|
||
PC/370 implements these instructions to allow students to
|
||
code, assemble, and execute ASSIST 370 programs on any 80x86 MS-
|
||
DOS based micro-computer rather than having to use an IBM 370
|
||
mainframe. This was the original objective for which PC/370 was
|
||
developed back in 1981. The first students to use PC/370 with
|
||
ASSIST were volunteers at the University of South Florida,
|
||
College of Engineering. The students used a CP/M based Z80
|
||
micro-computer with the original version of PC/370 instead of
|
||
the IBM 3033 mainframe ASSIST system accessed via RJE using
|
||
keypunched card decks.
|
||
|
||
B. ASSIST extended instructions
|
||
|
||
1. XFILI =C'filename'
|
||
|
||
This extended instruction redirects input source for XREAD.
|
||
If open, the current input source file is closed. The new
|
||
filename can be any standard MS-DOS path/filename ending
|
||
with suffix .xxx or a zero byte. If the filename is CON:
|
||
then the input source is the console with a ? prompt. To
|
||
set the ASSIST end of file condition code for XREAD from the
|
||
console, use the escape (ESC) key. See DEMOAST3.ALC for
|
||
demo of redirection.
|
||
|
||
2. XFILO =C'filename'
|
||
|
||
This extended instruction redirects the output from XPRNT.
|
||
If open, the current output file is closed. The new file
|
||
name can be any standard MS-DOS path/filename ending with
|
||
suffix .xxx or a zero byte. If the filename is CON: then
|
||
the output from XPRNT is directed to the console. The first
|
||
byte which is printer control code is also printed on
|
||
console.
|
||
|
||
3. XREAD area [,length]
|
||
|
||
Read record into area with default length of 80 padded with
|
||
blanks. If the input is coming from console, the first
|
||
carriage return defines end of record, and single ESC
|
||
character defines end of file. Note ASCII characters from
|
||
console or file are automatically translated to EBCDIC in
|
||
record area. Condition code set as follows:
|
||
|
||
0 - read successful
|
||
1 - end of file
|
||
|
||
Default input source is file named ASSIST.DAT. If the file
|
||
is not found, the input and output source is switched to
|
||
console.
|
||
|
||
4. XPRNT area [,length]
|
||
|
||
Print record from area with default length of 132. Trailing
|
||
blanks are stripped off. The first character is used as
|
||
standard ASCII print control character:
|
||
|
||
' ' - space means skip one line
|
||
'/' - slash means skip two lines
|
||
'1' - one means skip a page
|
||
'+' - means skip no lines
|
||
'-' - dash means skip three lines
|
||
|
||
Output to console includes print control character. Default
|
||
output is to file named ASSIST.PRN which is also used by
|
||
interactive debug X logging command and XDUMP.
|
||
|
||
5. XDECI reg,area
|
||
|
||
Read ASCII integer number from area and store into register.
|
||
Leading plus or minus signs may be present. Condition code
|
||
is set as follows:
|
||
|
||
0 - number is zero
|
||
1 - number less than zero
|
||
2 - number is greater than zero
|
||
3 - no number found in area
|
||
|
||
Register 1 is set to address of first character after number
|
||
read.
|
||
|
||
6. XDECO reg,area
|
||
|
||
Convert binary integer number in register to 12 character
|
||
display field with numeric value including sign.
|
||
|
||
7. XDUMP [area start, area end]
|
||
|
||
Dump general purpose registers (default with no args) or
|
||
dump area of memory to output file.
|
||
|
||
*********
|
||
|
||
Chapter 7. Interactive Debug Facility
|
||
|
||
*********
|
||
|
||
A. Overview
|
||
|
||
The PC/370 interactive debug facility is designed to provide a
|
||
tool to help debug program errors in either 80x86 code or 370
|
||
code. The facility provides the basic tools namely tracing
|
||
program flow via breakpoints defined by calls, and displaying
|
||
register and memory contents upon request. In addition, the
|
||
facility provides a data and address stop option which is very
|
||
useful for locating errors.
|
||
|
||
B. Program Interface
|
||
|
||
The PC/370 interactive debug facility is implemented via a single
|
||
module named MMDBUG which is linked into A370, L370 and E370
|
||
programs and is called with a single 3 byte ASCII argument
|
||
located immediately after the near call instruction. In the
|
||
E370 emulator environment, the interactive debugger can be called
|
||
directly from 370 programs through SVC 9 which must be followed
|
||
by 3 byte EBCDIC argument and a 1 byte filler to keep
|
||
instructions on half word boundary.
|
||
|
||
There are several special calling arguments as follows:
|
||
|
||
1. 'OFF' - turn off (kill) trace facility for speed
|
||
(a trace is killed by replacing call with jump over
|
||
the trace ID to the next instruction)
|
||
2. 'ON ' - turn trace facility back on (stop killing traces)
|
||
3. 'BUG' - force interactive debug mode
|
||
4. 'IOF' - interrupts off (unsolicited keys queued for input)
|
||
5. 'ION' - interrupts on (any key stroke invokes user
|
||
interface)
|
||
6. 'IFL' - instruction fetch loop (special trace used in E370
|
||
to identify next trace id as 370 operation trace to
|
||
be stored in trace table)
|
||
|
||
The first call to MMDBUG in A370, L370, and E370 is with 'OFF'
|
||
unless the trace option was requested via COM file parm or if the
|
||
debug option D was specified on link edit of COM or BIN file.
|
||
|
||
C. User Interface
|
||
|
||
When MMDBUG is called without the 'OFF' argument, or when a key
|
||
is hit without the 'IOF' argument being issued previously, the
|
||
user interface mode is invoked and the following commands may
|
||
be entered in upper or lower case from the console:
|
||
|
||
A - ADDRESS STOP (PROMPTS FOR ADDRESS, LENGTH, TYPE)
|
||
C - CONTINUE TO NEXT TRACE ENTRY
|
||
D - DUMP MEMORY (PROMPTS FOR ADDRESS)
|
||
F - FIND TRACE ENTRY (PROMPTS FOR TRACE ID)
|
||
H - HELP LIST MMDBUG COMMANDS (THIS LIST)
|
||
I - INSTRUCTION COUNTER WORD
|
||
J - RESET NEXT 370 OR 8086 INSTRUCTION ADDRESS
|
||
K - KILL MODE SET/RESET (kills or restores traces)
|
||
L - SET/RESET TRACE LIMIT FOR Q/T MODE
|
||
M - MODIFY MEMORY (PROMPTS FOR ADDRESS AND DATA)
|
||
N - LIST LAST 20 TRACE ENTRIES (NOTE K,Z AFFECT THIS LIST)
|
||
P - SET/RESET PRINT COPY OF ALL MMDBUG I/O
|
||
Q - SET QUIET MODE (USED WITH F, L, AND 'BUG' OPTIONS)
|
||
R - DISPLAY REGISTERS (SEE Z OPTION)
|
||
S - SAVE/UNSAVE CURRENT TRACE ID FROM KILL MODE
|
||
T - SET TRACE MODE (USED WITH OPTIONS F AND L)
|
||
W - LIST FREE MEMORY QUEUE
|
||
X - SET/RESET ASSIST LOGGING OF INTERACTIVE DEBUG OUTPUT
|
||
Y - MODIFY 8086/370 REGISTER (PROMPTS FOR REGISTER/DATA)
|
||
Z - SET/RESET 8086/370 MODE
|
||
IN 8086 MODE, R DUMPS 8086 REGISTERS AND D PRINTS
|
||
PRINTABLE ASCII CHARACTERS IN DUMP.
|
||
IN PC/370 MODE, R DUMPS 370 REGISTERS AND PSW
|
||
AND D DUMPS PRINTABLE EBCDIC CHARACTERS IN DUMP.
|
||
<cr> - dump same address again as defined in D command
|
||
<sp> - dump forward until any key hit
|
||
<bs> - dump backwards until any key hit
|
||
<esc>- exit to MSDOS after attempting to close files
|
||
|
||
Memory addresses may be entered in xxxx:xxxx or xxxxxx hex format
|
||
without leading zeros required. In 370 mode, the xxxxxx format
|
||
always refers to the relative address within the current address
|
||
space. In 80x86 mode, the xxxxxx format refers to the offset
|
||
using the current segment. The segment:offset is initialized to
|
||
the emulator data segment area containing the 370 registers.
|
||
|
||
D. User Guide
|
||
|
||
The PC/370 interactive debug facility can assist you in locating
|
||
errors within your 370 assembler programs. But first there are
|
||
some more basic things to check:
|
||
|
||
1. Are you sure that you are executing the latest version of
|
||
the source program. To be absolutely sure, code the date
|
||
and time in a print statement at the beginning of the program
|
||
and then reassemble (A370) and relink (L370) and execute the
|
||
program again.
|
||
|
||
2. Does the program run to normal termination? If so then you
|
||
can run the program again specifying a T as the only parameter
|
||
on the execute command to initiate the interactive debug
|
||
facility. Another way to invoke the interactive debug option
|
||
is to specify option D in the linkage editor. This method
|
||
should be used if the program requires a parameter other than
|
||
T.
|
||
|
||
3. If the program terminated abnormally, the interactive debug
|
||
facility is automatically initiated along with a display of
|
||
the PSW and the failing instruction. To calculate the
|
||
relative address of the failing instruction in the program,
|
||
subtract the program load address of X'0200' (Note you will
|
||
have to look at the link edit listing to get the starting
|
||
address if the failing instruction is in a subroutine.
|
||
|
||
4. To trace execution of the program, enter K once or twice to
|
||
restore all traces and then enter T. To stop the trace at any
|
||
point hit any key.
|
||
|
||
5. To continue execution of the program normally, enter Q.
|
||
For fast execution, use K command to set kill trace mode
|
||
first.
|
||
|
||
6. To dump the current contents of the registers, enter R.
|
||
|
||
7. To dump any 32 byte area in memory, enter A followed by
|
||
the starting address in hex xxxx.
|
||
|
||
8. To continue to dump memory from the current location forward,
|
||
hit the space key. To dump backwards, hit the backspace key.
|
||
To stop the dump, hit any key.
|
||
|
||
9. To stop the program at a specific address, enter A followed
|
||
by the address in hex xxxx followed by the option code A.
|
||
Then use Q or T to continue execution until the address is
|
||
found.
|
||
|
||
10. To stop the program when a specific data field in memory is
|
||
changed, enter A followed by the address in xxxx followed by
|
||
the option code E for equal data or N for not-equal data.
|
||
Next entry the length of the data compare in hex when
|
||
prompted. If option E is selected, enter the hex value of the
|
||
data you want to search for when prompted. Next press Q or T
|
||
to continue execution until the data compare specified
|
||
triggers debug user interface again. To stop at a specific
|
||
instruction count in a 370 program, use the I command to
|
||
display the instruction counter word and then use data equal
|
||
address stop on the word. To obtain detail instruction trace
|
||
up to point of failure, either use Q or T from beginning of
|
||
the program or set address stop at previous multiple of 256
|
||
on instruction count field and then restore traces with K
|
||
command and then use Q or T proceed to point of failure. At
|
||
point of failure, use N command to list last 20 instruction
|
||
trace points.
|
||
|
||
11. To turn off any address stop option, enter A.
|
||
|
||
12. To list the last 20 instruction trace table entries, enter N.
|
||
If running in 370 mode (option Z toggles mode), only the 370
|
||
instruction traces will be stored and listed via option N.
|
||
In 80x86 mode, all traces will be stored and listed.
|
||
Note that this list may be incomplete if the program
|
||
was running with K option active to kill traces for speed.
|
||
Option K kills each trace entry to debug the first time debug
|
||
is entered for that trace point. Option K makes the program
|
||
run much faster at the expense of losing repeated trace
|
||
points until K reset is issued. However, you can use Find to
|
||
locate selected trace id's and use Save to protect id from
|
||
kill mode. This option allows much faster execution while
|
||
still being able to trace selected id's. A very useful id to
|
||
save is IFL which will then trace each 370 instruction during
|
||
kill mode while killing all of the lower level ID's for
|
||
reasonable speed yet full visibility of 370 instructions.
|
||
Faster still is to save only one 370 instruction id such as
|
||
TRT. This is very useful in conjunction with address stop,
|
||
since the address stop overhead is only incurred for the
|
||
selected saved id's. Note that the trace table only contains
|
||
addresses of instructions, and as a result if instruction
|
||
modification or overlays are used, the data listed for a
|
||
previous instruction may be different from what it was at the
|
||
time it was executed. In this case it may be helpful to rerun
|
||
program with address stop to see what was in memory at the
|
||
time an instruction was executed.
|
||
|
||
13. To set a fixed limit on the number of trace entries before
|
||
entering debug command mode again, enter L and count in hex
|
||
xxxx. Next enter Q or T to continue until count reached zero.
|
||
If zero count is entered, the limit is not checked.
|
||
|
||
14. To modify memory, enter M followed by address in hex xxxx.
|
||
Next enter hex data bytes followed by return key.
|
||
|
||
15. To display the 8086 registers, type Z to switch to 8086 mode.
|
||
Now type R. In 8086 mode, storage dumps translate data to
|
||
ASCII instead of EBCDIC for character display. In 8086 mode,
|
||
N lists all trace entries instead of just IFL 370 instruction
|
||
traces. In 8086 mode, Y changes 8086 registers instead of 370
|
||
registers. To return to 370 mode, type Z again.
|
||
|
||
16. The W command displays free memory in the 8086 data segment
|
||
for 8086 mode and the free memory in the current address
|
||
space in 370 mode. Note these are two totally separate free
|
||
areas. The 8086 free area is limited to <= 64k addressable by
|
||
the DS register and uses 4 byte free queue elements
|
||
(next,length). The 370 free area extends from the end of 370
|
||
code in COM module to the end of free memory and uses 8 byte
|
||
370 format free queue elements (next,length) on 8 byte
|
||
boundaries. For BIN file execution, the free area is the SQA
|
||
area allocated in the emulator address space. The first free
|
||
queue element in a 370 address space is pointed to by ASCASF
|
||
field in address space control block located at X'104' in low
|
||
memory (may be zero if no free memory currently available).
|
||
The ASCB for BIN modules can be located by subtracting
|
||
(X'200'-X'104') from the entry point address in register 15 at
|
||
entry (trace ID 370).
|
||
|
||
17. The J jump command may be used to modify either the emulator
|
||
or the 370 current instruction address depending on the
|
||
current Z mode. In 370 mode, the address entered is a virtual
|
||
address. In 80x86 mode, the address entered is a code segment
|
||
offset (This is a very dangerous function and not
|
||
recommended).
|
||
|
||
*********
|
||
|
||
Chapter 8. Floating Point Support
|
||
|
||
*********
|
||
|
||
A. Register formats
|
||
|
||
1. General purpose registers
|
||
|
||
The general purpose 370 registers are located at the beginning
|
||
of the data segment of the E370 emulator (DS:0). They are
|
||
stored in 80x86/80x87 long integer format with least
|
||
significant byte first starting with register 0. For example,
|
||
the high byte of register 0 is at DS:3 and the low byte of
|
||
register 1 is at DS:4. This area can be used with address
|
||
stop to detect a specific register value or change in register
|
||
value (although remembering reverse format is always a
|
||
challenge). This format is used to allow native loads and
|
||
stores without reversing bytes which speeds up register to
|
||
register operations and allows addition of registers directly
|
||
from memory without conversion.
|
||
|
||
2. Floating point registers
|
||
|
||
If the 80x87 co-processor is installed, the R command displays
|
||
the four 8 byte floating point register values numbered 0, 2,
|
||
4, and 6. This is one way (other than 123 /WS screen) to tell
|
||
if 80x87 is installed. The floating point registers are
|
||
stored in 80x87 temporary real format which is 10 bytes long.
|
||
The first 8 bytes contain the normalized 64 bit unsigned
|
||
mantissa with the high bit always on stored in reverse order
|
||
(like a double long integer with the least significant byte at
|
||
low address. The last 2 bytes contain the base two exponent
|
||
and the sign stored as an integer. The 15 bit exponent is
|
||
stored in excess 3FFFH format. True zero is represented by
|
||
plus or minus sign and all other bits zero. This format
|
||
exceeds 370 double precision 8 byte format for both mantissa
|
||
and exponent range. This format is used to significantly
|
||
speed up floating point register to register operations since
|
||
numbers can be directly transferred to/from 80x87 in this
|
||
format. A conversion routine must be used to convert floating
|
||
point numbers when moved to/from memory to the floating point
|
||
registers. The conversion routine is quite efficient but does
|
||
involve shifting entire number up to 3 bits left or right to
|
||
convert from normalized base 2 to base 16. The floating point
|
||
register memory area can be dumped to see the real format and
|
||
can be used with address stop to detect specific value or
|
||
change in value.
|
||
|
||
B. Floating Point Scientific Subroutine Package
|
||
|
||
Using floating point 370 instructions plus extended 80x87 function
|
||
SVC's described in SYSTEM.DOC, a set of efficient scientific
|
||
subroutines have been coded in SSP.ALC and are stored in the
|
||
L370.LIB subroutine library. The argument and result is in F0 or
|
||
R0 unless noted otherwise. The SSP functions are similar to the
|
||
FORTRAN IV intrinsic functions.
|
||
|
||
FUNCTION DESCRIPTION RANGE LIMITATIONS NOTES
|
||
|
||
ATAN ARCTAN
|
||
ALOG LOG BASE E 0 < F0
|
||
ALOG10 LOG BASE 10 0 < F0
|
||
COS COSINE
|
||
EXP E ** X
|
||
REAL CVT TO REAL -2**32 <= R0 < 2**32 ARG. IN R0
|
||
INT CVT TO INT -2**32 <= F0 < 2**32 RESULT IN R0
|
||
MOD MOD(F0,F2) REMAINDER R0
|
||
PI PI 3.14159.............
|
||
SIN SINE
|
||
SQRT SQUARE ROOT 0 <= F0
|
||
TAN TANGENT
|
||
|
||
C. Floating point co-processor assisted standard 370 instructions.
|
||
|
||
1. If the floating point option is on and an 80x87 co-processor
|
||
is installed, then it is used to assist the CVB and CVD
|
||
instructions for speed. In the case of large numbers, the
|
||
speed improvement can be up to 4 times. For numbers close
|
||
to zero, there is no improvement in speed. Depending on
|
||
user demand, this type assist may be added for other packed
|
||
decimal instructions in the future.
|
||
|
||
*********
|
||
|
||
Chapter 9. XA Extended Architecture Support
|
||
|
||
*********
|
||
|
||
1. A370 supports the XA instructions as defined in the
|
||
IBM System/370 XA Principles of Operation manual version
|
||
SA22-7085.
|
||
|
||
2. E370 supports the 6 XA non-privileged instructions
|
||
BAS, BASR, MVCIN, BASSM, IPM, and BSM. When the emulator is in
|
||
31 bit mode, the PSW format displayed by MMDBUG is extended mode
|
||
with the high address bit on. The emulator defaults to 24 bit
|
||
mode and the 370 basic PSW format.
|
||
|
||
3. The standard instructions LA, BAL, BALR, EDMK, and TRT
|
||
now support both the 24 bit and 31 bit addressing modes
|
||
as set by BASSM or BSM using the PSW address mode bit.
|
||
Note that in 31 bit addressing mode the LA instruction
|
||
adds all 31 bits of the index and base register plus
|
||
displacement and clears only the high bit of the result. This
|
||
means the high byte of the index and base must be cleared when
|
||
using 24 bit addresses in 31 bit mode.
|
||
|
||
**********
|
||
|
||
Chapter 10. System subroutine library
|
||
|
||
**********
|
||
|
||
The following subroutines are included in the default system
|
||
subroutine relocatable library L370.LIB in the root directory:
|
||
|
||
# SUBROUTINE ENTRY FUNCTION ARGUMENTS
|
||
|
||
1 DAT print date and time none
|
||
|
||
2 TIMER return current time none
|
||
of day in R0 in 100th
|
||
of a second units
|
||
|
||
3 PET print elapsed time since none
|
||
last call plus date and
|
||
time and 370 instruction
|
||
count interval statistics
|
||
|
||
4 DTIME print time in upper left none
|
||
corner of screen in format
|
||
HH:MM:SS
|
||
|
||
5 SYNERROR print PC/370 input/output R0 = error code
|
||
error message based on R1 = function code
|
||
return codes passed in
|
||
registers R0-R1 at entry
|
||
to SYNAD DCB exit routine
|
||
|
||
6 SSP scientific subroutines
|
||
(see chapter 8 for entry
|
||
points to this module)
|
||
|
||
7 API support application using
|
||
application program interface
|
||
(API) with IBM PC 3270
|
||
emulation via interrupt 7A
|
||
|
||
The 370 source code for all of the above modules is in the LIB
|
||
directory, and the BAT\BLDLIB.BAT command file will rebuild library
|
||
from the source. Remember when adding subroutines to a relocatable
|
||
library that there cannot be any backward references to prior modules
|
||
in the library since L370.EXE uses serial one pass search for external
|
||
references in the library.
|
||
|
||
**********
|
||
|
||
Chapter 11. COBOL call interface support
|
||
|
||
**********
|
||
|
||
To call a PC/370 assembler subroutine from a Micro Focus COBOL program
|
||
requires that the PC/370 emulator E370R42.EXE be made resident by
|
||
executing it directly (see BAT\RUNCBL.BAT for demo). Each subroutine
|
||
to be called must be assembled and linked using option B to create a
|
||
BIN type file which will be dynamically loaded on the first call.
|
||
|
||
The interface performs the following functions prior to transferring
|
||
control to the assembler subroutine:
|
||
|
||
1. The address space control block at X'104' in the BIN file is
|
||
initialized to a virtual equals real (V=R) region in order to
|
||
address the arguments passed. The ASCASF free memory pointer
|
||
is initialized to point to the current first free queue element
|
||
in the common system queue area (SQA) memory allocated along
|
||
with the resident emulator. The SQA is used to dynamically
|
||
allocate buffers for subroutine file I/O and any other dynamic
|
||
memory requests via GETMAIN/FREEMAIN svc's. Note that SQA is
|
||
shared by all subroutines and each subroutine must release any
|
||
memory it uses prior to exit or SQA will eventually be depleted
|
||
(just like MVS).
|
||
|
||
2. The segment and offset argument addresses on the stack are
|
||
converted into a standard 370 calling list of 32 bit absolute
|
||
addresses located at X'80' in the BIN file (normally the command
|
||
line area). Up to 32 arguments can be passed.
|
||
|
||
3. The 370 registers are set as follows:
|
||
|
||
R1 = absolute address of argument list at X'80' in BIN file
|
||
|
||
R14 = absolute return address to exit subroutine at X'102' in
|
||
BIN file via detach SVC.
|
||
|
||
R15 = absolute address of entry point (normally X'210' in BIN
|
||
file. At exit from called BIN module, the low 16 bits of
|
||
register 15 are used to set special Micro Focus COBOL return
|
||
code value called RETURN-CODE. If emulator is not resident
|
||
when a BIN module is called, a return code of 16 is passed.
|
||
|
||
4. If option D was specified in the L370 link of the BIN module
|
||
being called, the emulator interactive debug facility will be
|
||
invoked at entry with all traces restored. If option D was
|
||
not specified, execution will proceed without interruption and
|
||
no traces will be restored to provide fast execution of one or
|
||
more BIN modules.
|
||
|
||
5. Note that BIN modules are dynamically loaded by COBOL run time
|
||
system at unknown addresses. Since BIN subroutines run in
|
||
V=R address mode in order to address COBOL data areas, all 370
|
||
subroutine code must be self relocating. See CBL\TESTCIO.ALC
|
||
for example of how to relocate any address constants required
|
||
such as subroutine entry points and DCB addresses. The A370
|
||
assembler lists all relocation addresses in PRN listing created
|
||
with the /L option.
|
||
|
||
**********
|
||
|
||
Chapter 12. Technical References:
|
||
|
||
**********
|
||
|
||
1. For information on 370 machine instructions see
|
||
IBM System 370 XA Principles of Operation manual SA22-7085.
|
||
2. For information on 370 assembler language see:
|
||
a. IBM OS/VS Assembler Language manual GC33-4010.
|
||
b. Assembler Language Programming by G. W. Struble.
|
||
3. For information on how the assembler, linkage editor, and
|
||
operating system software works see:
|
||
a. Systems Programming by John J. Donovan.
|
||
b. Operating Systems by S. E. Madnick and J. J. Donovan.
|
||
4. For information on the 80x86 processors see:
|
||
a. The 8086 Book by George Alexy.
|
||
b. Intel iAPX 286 Programmer's Reference Manual 210498-003.
|
||
c. Intel 80386 Programmer's Reference Manual 230985-001.
|
||
5. For information on the MSDOS operating system and utilities
|
||
see:
|
||
a. Disk Operating System Version 3.2 Reference 68X2405.
|
||
b. Disk Operating System Technical Reference 6139658.
|
||
c. Advanced MS-DOS by Microsoft Press ISBN 0-914845-77-2
|
||
6. For information on usage of ASSIST extensions see:
|
||
a. Assembler Language with Assist by Ross A. Overbeek and W.
|
||
E. Singletary. Published by Science Research Associates,
|
||
Inc., Chicago, Copyright 1976, ISBN 0-574-21085-7.
|
||
b. IBM 370 Assembly Language with ASSIST, Structured Concepts,
|
||
and Advanced Topics by Charles J. Kacmar. Published by
|
||
Prentice Hall, September 1987, ISBN 0-13-455742-5.
|
||
7. For summary article on how PC/370 was developed see ACM
|
||
Sigsmall Newsletter Volume 8 Number 3, August 1982.
|
||
8. For article on conversion of PC/370 from CP/M to MS-DOS see
|
||
ACM SIGSMALL/PC Newsletter Volume 11 Number 3, August 1985.
|
||
9. For information on 80x87 see Intel iAPX 286 Programmer's
|
||
Reference Manual #210498-003. Also book by designer titled,
|
||
"The 8087 Primer" by John F. Palmer and Stephen P. Morse,
|
||
published by John Wiley & Sons, inc. Copyright 1984, ISBN 0-
|
||
471-87569-4. |