1. Redesign and correct implementation of the "normalization limiter
digit" in floating add/subtract.
2. Correct final value of A register when floating-overflow occurs in
floating multiply.
3. Correct final value of A register when D register is not normalized
for floating divide.
4. Correct register setup and post-divide normalization for floating
divide.
5. Implement double-click handler on Cardatron reader and printer
background panel areas to temporarily toggle their speeds by 1000
cards/lines per minute. This is intended only for testing, not for
regular use.
6. Implement double-click handler on Console Burroughs logo to toggle
lamp intensity averaging on and off temporarily.
7. Implement validation of magnetic tape image files during loading;
reject image files that do not pass.
8. Minor changes to comments and cosmetics for multiple other scripts.
1. Rework Processor internal timing and throttling mechanism during I/O.
2. Revise Console statistics display, add instruction counter.
3. Correct (again) CFA/CFR instruction when sign is included in field.
4. Correct B-register modification of words during Cardatron and
magnetic tape input.
5. Clear Processor alarms on Reset/Transfer.
6. Add links to wiki on index and home pages.
7. Eliminate B220Util CSS class functions in favor of DOM classList
methods.
8. Attempt to reproduce "Sundland Beige" color for the panels.
9. Correct formatting of tab stops for B220ConsolePrinter.
10. Reduce Whippet printer speed from 5000 to 1000 cps.
11. Reduce Console update frequency from every 50 to 100 ms; increase
lamp glow update factor from 0.25 to 0.75.
12. Allow click of white button below console register lamps in addition
to clicking the lamps themselves to toggle the lamp state.
13. Rework the way that white vertical bars are drawn on registers.
14. Allow B220PaperTapeReader to properly send sign-2 alphanumeric words
with trailing spaces if the tape image file has been space-trimmed on
the right.
15. Clear the paper tape reader view window when loading new tapes.
16. Revise yet again the setCallback() delay deviation adjustment
algorithm.
1. Remove Application Cache mechanism (has been deprecated as a web standard).
2. Replace internal bindMethod() utility function with standard Javascript object.bind().
3. Automatically reset Digit Check Alarm when bits are corrected in registers.
4. Correct setting of Overflow Toggle in IFL.
5. Terminate magnetic tape data transfer if AST toggle gets reset.
6. Correct way Processor was released by magnetic tape TCU.
7. Correct construction of preface word in memory for mag tape MRR.
8. Correct determination of mag tape "remote" status to allow tape to be unloaded immediately after a rewind.
9. Fix bug in BCS detecting the switch setting.
10. Modify behavior of Reset/Transfer switch to allow recovery after a tape malfunction.
11. Correct formatting of HIGH lamp on Control Console.
12. Remove extraneous whitespace from B220FramePaper sub-window markup.
1. Commit initial (incomplete) implementation of magnetic tape drives (TSU) and control: MLS, MRW, MDA, MIW, MIR, MPF, MPB, MPE, MIB, MIE.
2. Change B220SetCallback.js "setImmediate" mechanism to use DOM Promises instead of window.postMessage().
3. Minor styling and window positioning changes.
1. Finish implementation of Cardatron input and output units.
2. Minor corrections to BAC-Assembler script and BALGOL-Generator transcription.
3. Apply band-select "punches" in column 1 of WINTER.PI.card assembler deck.
4. Implement striping on Console register displays to highlight the opcode (62) fields.
5. Implement List-Cards utility to read cards from CR1 and list them on LP2.
1. Rework the partial-word operators for better efficiency.
2. Correct emulated processor clock update during I/O operations.
3. Centralize common I/O initialization and termination code.
4. Correct statistics calculations in schedule().
5. Correct timing for integer and floating divide operators.
6. Correct remainder shifting in floating divide.
7. Implement diagnostic monitor window, opened by double-click on retro-220 logo on home page.
8. Correct timing for ConsolePrinter carriage control functions.
9. Implement simple demo programs pre-loaded into memory.
1. Implement console teletype printer and paper tape punch devices.
2. Correct timing mechanism and operation complete processing for asynchronous (I/O) processor mode.
3. Delete extraneous alarm toggles from B220Processor.
4. Correct Reset And Transfer switch so it will work when the Processor is running.
5. Implement Hello World default program for SPO at address 0020.
6. Change keyboard keystroke assignments for B220ConsoleKeyboard.
7. Implement Reset-to-Defaults feature for B220SystemConfig.
8. Implement DOM Element.classList for B220Util class attribute manipulation.
9. Minor typo correction to BALGOL-Generator.bacg.