! Fix issues with DEUNA driver ! ! Three items: ! 1. Non-zero unit number was handled as unit zero. ! 2. Close would mishandle non-zero unit numbers. ! 3. User receive completion did not give the buffers back to active receive. ! ! This is a Monitor patch, developed for V10.1; it might work on older versions. ! ! Paul Koning, 20-Nov-23 ! File to patch? Module name? UNA Base address? XEDVRM@OVR Offset address? 2170 Base Offset Old New? ?????? 002170 016661 ? 116661 ?????? 002172 000004 ? ^Z Offset address? 2404 Base Offset Old New? ?????? 002404 016100 ? 10005 ?????? 002406 000004 ? 16100 ?????? 002410 116105 ? 4 ?????? 002412 177767 ? 240 ?????? 002414 016505 ? ^Z Offset address? 6002 Base Offset Old New? ?????? 006002 004767 ? 4737 ?????? 006004 006606 ? PATCH@RSTS ?????? 006006 012677 ? ^Z Offset address? ^Z Base address? ^Z Module name? RSTS Base address? PATCH Offset address? 0 Base Offset Old New? ?????? 000000 000000 ? 4737 ?????? 000002 000000 ? XEDVRM@OVR+14614 ?????? 000004 000000 ? 12737 ?????? 000006 000000 ? 34240 ?????? 000010 000000 ? 177776 ?????? 000012 000000 ? 4737 ?????? 000014 000000 ? XEDVRM@OVR+15336 ?????? 000016 000000 ? 12737 ?????? 000020 000000 ? 34140 ?????? 000022 000000 ? 177776 ?????? 000024 000000 ? 207 ?????? 000026 000000 ? ^C