The save/restore format has been updated to improve its reliability. As a result, save files prior to release 3.0 are no longer supported. The text documentation files are obsolete and are no longer included with the distribution. Up-to-date PDF documentation files are available on the SimH web site. 1. New Features 1.1 3.6-0 1.1.1 Most magnetic tapes - Added support for limiting tape capacity to a particular size in MB 1.1.2 IBM 7090/7094 - First release 1.1.3 VAX-11/780 - Added FLOAD command, loads system file from console floppy disk 1.1.4 VAX, VAX-11/780, and PDP-11 - Added card reader support (from John Dundas) 1.1.5 PDP-11 - Added instruction history 2. Bugs Fixed Please see the revision history on http://simh.trailing-edge.com or in the source module sim_rev.h.
73 lines
3.4 KiB
Plaintext
73 lines
3.4 KiB
Plaintext
Bugs found
|
|
|
|
1. CPU: MPY tested sign of AC instead of sign of MQ.
|
|
2. CPU: VLM, VDP, VDH need alternate opcode decode points for large counts.
|
|
3. CPU: STL not in decode table.
|
|
4. CPU: Partial stores lacked initial read in decode table.
|
|
5. CPU: PXD, PCD needed (t_uint64) cast.
|
|
6. CPU: SXD, SCD needed (t_uint64) cast.
|
|
7. CPU: SBM at wrong case offset.
|
|
8. CPU: All transfers used IR<21:35> instead of calculated effective address.
|
|
9. CPU: HPR, TRA need alternate negative opcodes.
|
|
10. CPU: STT missing final write to memory.
|
|
11. IO: Channel output process model incorrect, extensive revision required.
|
|
12. IO: Channel connect test should not test channel state, only connection.
|
|
13. IO: Channel opcode with nostore doesn't increment channel address.
|
|
14. CDR: Card reader missing activate at end of state 2.
|
|
15. SYS: Zero operand instructions printed with trailing space.
|
|
16. CPU: Convert class count bit field start definition incorrect.
|
|
17. CPU: CAQ cut and paste error from CVR.
|
|
18. CPU: Shift count is 8b wide, not 9b.
|
|
19. SYS: Mnemonic is LDQ not LMQ.
|
|
20. SYS: RQL opcode incorrect in symbolic decode table.
|
|
21. CPU: Multi-tag mode stores OR'd value of tags on any index read except
|
|
normal effective address.
|
|
22. CPU: Floating point trap does not write location 0 if trap suppressed.
|
|
23. SYS: TRA instructions should have symbolic class MXN not MXR.
|
|
24. CPU: Floating add instructions test for zero result only if normalization enabled.
|
|
25. CPU: Floating add with unlike signs and equal magnitudes, result sign is sign
|
|
of SR rather than sign of AC.
|
|
26. CPU: Floating multiply does not test spill prior to normalization step.
|
|
27. CPU: Channel activity proceeds under HALT.
|
|
28. MT: Any read error should stop the channel and the tape controller.
|
|
29. MT: EOR write flag cleared before testing.
|
|
39. IO: EOR write flag set after data sent to device.
|
|
40. IO: EOR write flag incorrect set on IOCP, IOCT, IOSP, IOST.
|
|
41. MT: End of file errors not masked on backspace operations.
|
|
42. CPU: LCHx, RCHx miscoded in decode table.
|
|
43. IO: Only 7607 error completions (IOxT without new command) set trap.
|
|
44. CPU: 7067 channel trap flags misdefined with extraneous decrement shift.
|
|
45. CPU: pcq array misdeclared as uint32 instead of uint16.
|
|
46. IO: SDC and SCD tested chan_flags instead of chan_dev.flags.
|
|
47. SYS: 7907 opcodes defined incorrectly.
|
|
48. SYS: TCH not decoding bit<19>.
|
|
49. IO: CTL not clearing EOR after device end.
|
|
50. DSK: Format code not incrementing track in writing all tracks in cylinder.
|
|
51. DSK: THA mode overwrites record structure of first record.
|
|
52. DSK: Write doesn't set channel request for initial word.
|
|
53. DSK: Saved record number was command digits 3..8 instead of 5..10.
|
|
54. CLK: Compute 60th's from location 5, so Chrono clock is in sync with interval clock.
|
|
55. CPU: Enable Chronolog clock if CTSS.
|
|
56. CPU: Read/write protection error not setting protection trap.
|
|
57. CPU: SCHx not setting protection trap in user mode.
|
|
58: CPU: Protection trap overwriting wrong location.
|
|
59. CPU: Stop message reporting physical, not virtual, PC.
|
|
60. IO: Test for "request another cycle" in channel processor was inverted.
|
|
61. IO: Valid bit handling incorrect across multiple transfers.
|
|
62. IO: BSR doesn't set EOF indicator.
|
|
63. IO: 7607 channel modeled incorrectly, could stall.
|
|
64. IO: All 7607 "effective NOP" conditions must be tested when a new command is
|
|
decoded (wc == 0 for IOCx and IOSx, EOR set for IOSx and IORx).
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|