1
0
mirror of https://github.com/PDP-10/its.git synced 2026-01-13 15:27:28 +00:00

Make ITS check whether the Type 340 display is up and running.

Now that ITS will honor the DSDP switch, it might not check the CONI
DIS bit 0 to see if the 340 is available.  This leads to a situation
where the display could be turned off but ITS thinks it's always
online and will try to use it.

This commit adds a check writing some CONO bits and read them back
with CONI.
This commit is contained in:
Lars Brinkhoff 2021-07-23 09:12:16 +02:00
parent 23f0a64b1c
commit 35b59c63e8

View File

@ -2650,7 +2650,10 @@ ADSDV: ;A HAS NEW 340MD
CONO DIS,0
CONI DIS,T
JUMPE T,ADSDVN ;DIS NOT AVAIABLE
ADSDV1: SKIPL T,DISUSR
ADSDV1: CONO DIS,DISCHN
CONSO DIS,7
JRST ADSDVN ;DIS NOT RUNNING
SKIPL T,DISUSR
CAMN U,DISUSR
JRST ADSDVY ;YES
CAME U,UMASTER