Make ITS check whether the Type 340 display is up and running.
Now that ITS will honor the DSDP switch, it might not check the CONI DIS bit 0 to see if the 340 is available. This leads to a situation where the display could be turned off but ITS thinks it's always online and will try to use it. This commit adds a check writing some CONO bits and read them back with CONI.
This commit is contained in:
parent
23f0a64b1c
commit
35b59c63e8
@ -2650,7 +2650,10 @@ ADSDV: ;A HAS NEW 340MD
|
||||
CONO DIS,0
|
||||
CONI DIS,T
|
||||
JUMPE T,ADSDVN ;DIS NOT AVAIABLE
|
||||
ADSDV1: SKIPL T,DISUSR
|
||||
ADSDV1: CONO DIS,DISCHN
|
||||
CONSO DIS,7
|
||||
JRST ADSDVN ;DIS NOT RUNNING
|
||||
SKIPL T,DISUSR
|
||||
CAMN U,DISUSR
|
||||
JRST ADSDVY ;YES
|
||||
CAME U,UMASTER
|
||||