mirror of
https://github.com/UtilitechAS/amsreader-firmware.git
synced 2026-02-06 00:25:55 +00:00
Multipliers for HAN data
This commit is contained in:
@@ -2,7 +2,7 @@
|
||||
#include "lwip/def.h"
|
||||
#include "Timezone.h"
|
||||
|
||||
IEC6205675::IEC6205675(const char* d, uint8_t useMeterType, uint8_t distributionSystem, CosemDateTime packageTimestamp, HDLCConfig* hc) {
|
||||
IEC6205675::IEC6205675(const char* d, uint8_t useMeterType, MeterConfig* meterConfig, CosemDateTime packageTimestamp, HDLCConfig* hc) {
|
||||
double val;
|
||||
char str[64];
|
||||
|
||||
@@ -360,12 +360,35 @@ IEC6205675::IEC6205675(const char* d, uint8_t useMeterType, uint8_t distribution
|
||||
lastUpdateMillis = millis();
|
||||
}
|
||||
|
||||
if(meterConfig->wattageMultiplier > 0) {
|
||||
activeImportPower = activeImportPower > 0 ? activeImportPower * (meterConfig->wattageMultiplier / 1000.0) : 0;
|
||||
activeExportPower = activeExportPower > 0 ? activeExportPower * (meterConfig->wattageMultiplier / 1000.0) : 0;
|
||||
reactiveImportPower = reactiveImportPower > 0 ? reactiveImportPower * (meterConfig->wattageMultiplier / 1000.0) : 0;
|
||||
reactiveExportPower = reactiveExportPower > 0 ? reactiveExportPower * (meterConfig->wattageMultiplier / 1000.0) : 0;
|
||||
}
|
||||
if(meterConfig->voltageMultiplier > 0) {
|
||||
l1voltage = l1voltage > 0 ? l1voltage * (meterConfig->voltageMultiplier / 1000.0) : 0;
|
||||
l2voltage = l2voltage > 0 ? l2voltage * (meterConfig->voltageMultiplier / 1000.0) : 0;
|
||||
l3voltage = l3voltage > 0 ? l3voltage * (meterConfig->voltageMultiplier / 1000.0) : 0;
|
||||
}
|
||||
if(meterConfig->amperageMultiplier > 0) {
|
||||
l1current = l1current > 0 ? l1current * (meterConfig->amperageMultiplier / 1000.0) : 0;
|
||||
l2current = l2current > 0 ? l2current * (meterConfig->amperageMultiplier / 1000.0) : 0;
|
||||
l3current = l3current > 0 ? l3current * (meterConfig->amperageMultiplier / 1000.0) : 0;
|
||||
}
|
||||
if(meterConfig->accumulatedMultiplier > 0) {
|
||||
activeImportCounter = activeImportCounter > 0 ? activeImportCounter * (meterConfig->accumulatedMultiplier / 1000.0) : 0;
|
||||
activeExportCounter = activeExportCounter > 0 ? activeExportCounter * (meterConfig->accumulatedMultiplier / 1000.0) : 0;
|
||||
reactiveImportCounter = reactiveImportCounter > 0 ? reactiveImportCounter * (meterConfig->accumulatedMultiplier / 1000.0) : 0;
|
||||
reactiveExportCounter = reactiveExportCounter > 0 ? reactiveExportCounter * (meterConfig->accumulatedMultiplier / 1000.0) : 0;
|
||||
}
|
||||
|
||||
threePhase = l1voltage > 0 && l2voltage > 0 && l3voltage > 0;
|
||||
if(!threePhase)
|
||||
twoPhase = (l1voltage > 0 && l2voltage > 0) || (l2voltage > 0 && l3voltage > 0) || (l3voltage > 0 && l1voltage > 0);
|
||||
|
||||
// Special case for Norwegian IT/TT meters that does not report all values
|
||||
if(distributionSystem == 1) {
|
||||
if(meterConfig->distributionSystem == 1) {
|
||||
if(threePhase) {
|
||||
if(l2current == 0.0 && l1current > 0.0 && l3current > 0.0) {
|
||||
l2current = (((activeImportPower - activeExportPower) * sqrt(3)) - (l1voltage * l1current) - (l3voltage * l3current)) / l2voltage;
|
||||
|
||||
Reference in New Issue