List #1 (0x01) (time is 1506275242) consumption is 601 Watts # One sample of each list on the Kaifa MA304H3E meter
E6 E7 00 0F 40 00 00 00 (Samples are captured from my meter and the breakdown and values are from ![Kaifa HAN OBIS codes](Documentation/Kaifa%20HAN%20OBIS%20codes%20KFM_001.pdf). Please note that units and/or data types in this document doesn't seem to be right. E.g. my total meter reading is 403 kWh, not the tenfold. Hopefully, the current is also closer to 1A than 1000A in each wire)
09 0C 07 E1 09 18 07 11 2F 16 FF 80 00 00 (String, 12 bytes, "")
02 01
06 00 00 02 59
List #2 (0x0D) (time is 1506275240) ## List #1 (0x01) (time is 1506275242) consumption is 601 Watts
E6 E7 00 0F 40 00 00 00 Data | Explaination | Value
09 0C 07 E1 09 18 07 11 2F 14 FF 80 00 00 02 0D ---- | ------------ | -----
09 07 4B 46 4D 5F 30 30 31 E6 E7 00 0F 40 00 00 00 | Uknown |
09 10 36 39 37 30 36 33 31 34 30 31 37 35 33 39 38 35 09 0C 07 E1 09 18 07 11 2F 16 FF 80 00 00 | Date and time | 2017-09-24 17:47:22
09 08 4D 41 33 30 34 48 33 45 02 01 | List Identifier | 0x01 = List #1
06 00 00 02 5C 06 00 00 02 59 | Active power+ (Q1+Q4) | 0.601 kW
06 00 00 00 00
06 00 00 00 00
06 00 00 01 19
06 00 00 06 BD
06 00 00 05 BA
06 00 00 08 86
06 00 00 09 60
06 00 00 00 00
06 00 00 09 78
List #3 (0x12) (time is 1506247210) ## List #2 (0x0D) (time is 1506275240)
E6 E7 00 0F 40 00 00 00 Data | Explaination | Value
09 0C 07 E1 09 18 07 0A 00 0A FF 80 00 00 02 12 ---- | ------------ | -----
09 07 4B 46 4D 5F 30 30 31 E6 E7 00 0F 40 00 00 00 | Unknown |
09 10 36 39 37 30 36 33 31 34 30 31 37 35 33 39 38 35 09 0C 07 E1 09 18 07 11 2F 14 FF 80 00 00 | Date and time | 2017-09-24 17:47:20
09 08 4D 41 33 30 34 48 33 45 02 0D | List Identifier | 0x0D = List #2
06 00 00 01 BA 09 07 4B 46 4D 5F 30 30 31 | OBIL List version identifier | KFM_001
06 00 00 00 00 09 10 36 39 37 30 36 33 31 34 30 31 37 35 33 39 38 35 | Meter -ID (GIAI GS1 -16 digit ) | 6970631401753985
06 00 00 00 00 09 08 4D 41 33 30 34 48 33 45 | Meter type | MA304H3E
06 00 00 01 01 06 00 00 02 5C | Active power+ (Q1+Q4) | 0.604 kW
06 00 00 04 92 06 00 00 00 00 | Active power - (Q2+Q3) | 0.000 kW
06 00 00 05 94 06 00 00 00 00 | Reactive power + (Q1+Q2) | 0.000 kVAr
06 00 00 05 A7 06 00 00 01 19 | Reactive power - (Q3+Q4) | 0.281 kVAr
06 00 00 09 62 06 00 00 06 BD | IL1 Current phase L1 | 1725 A
06 00 00 00 00 06 00 00 05 BA | IL2 Current phase L2 | 1466 A
06 00 00 09 73 06 00 00 08 86 | IL3 Current phase L3 | 2182 A
09 0C 07 E1 09 18 07 0A 00 0A FF 80 00 00 06 00 00 09 60 | ULN1 Phase voltage 4W meter, Line voltage 3W meter | 2400 V
06 00 06 27 21 06 00 00 00 00 | ULN2 Phase voltage 4W meter, Line voltage 3W meter | 0 V
06 00 00 00 00 06 00 00 09 78 | ULN3 Phase voltage 4W meter, Line voltage 3W meter | 2424 V
06 00 00 03 5A
06 00 00 DA AE ## List #3 (0x12) (time is 1506247210)
Data | Explaination | Value
---- | ------------ | -----
E6 E7 00 0F 40 00 00 00 | Unknown |
09 0C 07 E1 09 18 07 0A 00 0A FF 80 00 00 | Date and time | 2017-09-24 10:00:10
02 12 | List Identifier | 0x12 = List #3
09 07 4B 46 4D 5F 30 30 31 | OBIL List version identifier | KFM_001
09 10 36 39 37 30 36 33 31 34 30 31 37 35 33 39 38 35 | Meter -ID (GIAI GS1 -16 digit ) | 6970631401753985
09 08 4D 41 33 30 34 48 33 45 | Meter type | MA304H3E
06 00 00 01 BA | Active power+ (Q1+Q4) | 0.442 kW
06 00 00 00 00 | Active power - (Q2+Q3) | 0.000 kW
06 00 00 00 00 | Reactive power + (Q1+Q2) | 0.000 kVAr
06 00 00 01 01 | Reactive power - (Q3+Q4) | 0.257 kVAr
06 00 00 04 92 | IL1 Current phase L1 | 1170 A
06 00 00 05 94 | IL2 Current phase L2 | 1428 A
06 00 00 05 A7 | IL3 Current phase L3 | 1447 A
06 00 00 09 62 | ULN1 Phase voltage 4W meter, Line voltage 3W meter | 2402 V
06 00 00 00 00 | ULN2 Phase voltage 4W meter, Line voltage 3W meter | 0 V
06 00 00 09 73 | ULN3 Phase voltage 4W meter, Line voltage 3W meter | 2419 V
09 0C 07 E1 09 18 07 0A 00 0A FF 80 00 00 | Clock and date in meter | 2017-09-24 10:00:10
06 00 06 27 21 | Cumulative hourly active import energy (A+) (Q1+Q4) | 403 233 kWh
06 00 00 00 00 | Cumulative hourly active export energy (A-) (Q2+Q3) | 0 kWh
06 00 00 03 5A | Cumulative hourly reactive import energy (R+) (Q1+Q2) | 858 kWh
06 00 00 DA AE | Cumulative hourly reactive export energy (R-) (Q3+Q4) | 55 982 kWh