/TSS-8.25 CONFIGURATION FOR REMCO OF RACINE
/CONFIGURATION PARAMETERS FOR THE TSS/8 MONITOR
/COPYRIGHT 1971 - DIGITAL EQUIPMENT CORPORATION; MAYNARD, MASS.
/
/TSS-8 SYSTEM PARAMETERS AND OPTIONS. FOR EACH PARAMETER,
/THE COMMENT INIDCATES THE POSSIBLE RESPONSES.
DEBUG= 2 /SYSTEM DEBUGGING CONTROL:
/ =0, PRODUCTION SYSTEM (AUTO-RESTARTS & ERROR FIXUP)
/ =1, SYSTEM RELIABILITY (JUST AUTO-RESTARTS)
/ =2, SYSTEM DEBUGGING (SYSTEM HALTS ON ERROR)
/ =3, FULL CHECKING (THOROUGH 'RETB' CHECK)
/BITS 0-8, AVAILABLE FOR LOCAL SWITCHES:
/ 4000 - ENABLE MQ MEMORY DISPLAY (IN TIMER)
CPU= 2 /0 IF CPU IS PDP-8/I; 1 IF PDP-8
/ 2 IF PDP-8/E; 3 IF PDP-12; 4 IF PDP-8/A
EAE= 0 /20 IF CPU INCLUDES EAE; 0 IF NOT
CORMEM= 30 /HIGHEST DATA FIELD SELECT; FOR 12K SYS,
/ RESPOND 20; FOR 16K, RESPOND 30; FOR 32K, 70
D680= 0 /2 IF TTY INTERFACING IS 680 OR DC08;
/ 0 IF TTY INTERFACING IS PT08'S
PHONES= 0 /1 IF 680 OR DC08 INCLUDES 689 OR DC08F;
/ 0 IF IT DOESN'T OR TTY INTERFACING IS PT08'S
RF08= 0 /40 IF SYSTEM DISC IS DF32; 0 IF RF08
RS08= 1 /# OF DISCS IN SYSTEM, WHETHER RF08 OR DF32
RK05= 0 /# OF NONSYSTEM RK05 DRIVES
RK8E= 0 /# OF RK8E DRIVES; ONLY FIRST IS USED FOR SYSTEM
/ THE REMAINDER ARE TREATED AS PERIPHERALS
READER= 1 /1 IF SYSTEM INCLUDES HIGH-SPEED READER; 0 IF NOT
PUNCH= 0 /1 IF SYS HAS HSP, 0 IF NOT
TC01= 1 /1 IF SYS HAS DECTAPES; 0 IF NOT
TD8E= 0 /1 IF TD8E DECTAPES AVAILABLE FOR LOADING & DUMPING
/ 0 IF NOT; NOTE THAT TD8E TAPES CANNOT BE USED UNDER
/ TSS/8, THEY REQUIRE CONTINUOUS CPU ATTENTION
LPT= 3 /0 IF NO PRINTER ON SYS; 1 IF LP08; 2 IF LS8E; 3 IF NONSTANDARD
CDR= 0 / =1, IF CARD READER
/
/MONITOR OPTIONS
/FILL IN THE FOLLOWING LINES TO INDICATE THE
/MONITOR CAPACITY FOR THIS SYSTEM
DECIMAL
JOBMAX= 6 /NUMBER OF SIMULTANEOUS USERS (.LE. 20)
CONTTY= 1 / (ALWAYS HAVE A CONSOLE)
DC08A= 0 /NUMBER OF TERMINALS VIA DC08A (PDP-8/I ONLY, 19 MAX)
DC08LO= 0 /LOWEST LINE-NUMBER USED ON DC08A
PT08= 0 /NUMBER OF TERMINALS VIA PT08 (PDP-8 & PDP-8/I ONLY)
KL8= 15 /NUMBER OF TERMINALS VIA KL8E (PDP-8/E ONLY, 19 MAX)
CDVIN= 3 /NONSTANDARD INPUT CHARACTER DEVICES (HIGHEST USED)
/ 1 = R2; 2 = X0; 3 = X1; 4 = X2; 5 = X3
CDVOUT= 4 /NONSTANDARD OUTPUT CHARACTER DEVICES (HIGHEST USED)
/ 1 = P2; 2 = L2; 3 = Y0; 4 = Y1; 5 = Y2; 6 = Y3
TRUKBD= 3 /NUMBER OF ACTUAL KEYBOARDS ON SYSTEM (NOT COUNTING
/ CONSOLE TTY). THIS MUST BE .LE. NULINE; NULINE
/ MAY INCLUDE DUMMY TERMINALS, THIS MAY NOT.
FRCMAX= TRUKBD /THE HIGHEST KEYBOARD # A '00XX' ACCT # MAY FORCE
/ NOTE THAT A '000X' ACCOUNT MAY FORCE UP TO 'NULINE'
TLKMAX= TRUKBD /THE HIGHEST KEYBOARD # WHICH MAY BE 'TALK'ED TO
BRDMAX= TRUKBD /THE HIGHEST KEYBOARD WHICH WILL RECEIVE BROADCASTS
OCTAL
DTAMIN= 2 /THE FIRST DECTAPE DRIVE WHICH WILL BE ASSIGNED
/ FOR 'ASSIGN D' COMMAND; NORMALLY =0, BUT MAY
/ VARY FOR SLIGHTLY RESTRICTED DRIVE USE.
BILLNG= 7 /THE ACCOUNT NUMBER OF THE BILLING SYSTEM
/ 0, IF NO BILLING SYSTEM USED
/
/SYSTEM CONSTANTS
INFLD= 20 /FIELD SELECT THAT 'INIT' SHOULD BE BOOTED INTO
/ MAKING IT 20 AVOIDS PROBLEMS SHOULD A
/ FIELD NEED REPAIR & SYSTEM IS RUN ON 12K
TTYEVEN=1 /1 INDICATES PARITY TTY MAY BE USED WITH SYS
/ 0 ALLOWS ONLY DEC MODIFIED TTYS
/// END OF SYSTEM CONFIGURATION PARAMETERS