Tony Lawrence f75592c5b8 PDP11: 11/70 read-only registers must not return NXM on write
17 777 740 - 17 777 742, read-only error address registers,
and 17 777 764, a read-only System ID register,

and are not handled in the CPU70_wr() routine, which means for these
addresses the routine returns NXM, which then translates to "bus timeout"
(no response to address), and then, as a result, trap to vector 4.

That is incorrect, IMO.

These locations are read-only yet the address gets decoded, and even
though writing does not have any effect, the write routine for these
addresses should return SCPE_OK.