1
0
mirror of https://github.com/rcornwell/sims.git synced 2026-01-19 09:28:10 +00:00

README: Updated to indicated current status.

This commit is contained in:
Richard Cornwell 2017-01-22 23:06:27 -05:00
parent cda2a5dd8c
commit afa2270d30

106
README.md
View File

@ -1,33 +1,35 @@
# Development Simulators.
This is a working copy of my Burroughs B5500, KA10, KI10 and IBM7000 series
simulators for SimH.
B5500:
# Burroughs B5500
This is the same version as in the current simH source tree. It is working
correctly as far as I am able to tell. It will currently run MCP XIII and XV.
KA10 & KI10:
# Dec KA10 & KI10
These are still in the testing stages. Please report any issues that you find in them.
The KA10 sim has successfully run Tops 10 5.03 and Tops 10 6.03.
The KI10 sim has successfully passed the DBKA? through DBKE? diagnostics,
KI10 will boot TOPS10, however it is still unstable.
The KA10 sim has successfully run Tops 10 5.03 and Tops 10 6.03.
The KI10 sim has successfully run Tops 10 6.03
Started adding support for KA10 to boot ITS
Disk
RC10 RD10/RM10
RP10 RP01/RP02/RP03
RH10 RP04/RP06/RP07 (RP07 not supported under 6.03).
* RC10 RD10/RM10
* RP10 RP01/RP02/RP03
* RH10 RP04/RP06/RP07 (RP07 not supported under 6.03).
Tape
TM10A or B
* TM10A or B
Paper Tape
Punch
Reader
* Punch
* Reader
DC10E terminal mux.
The RP10 supports boot (actual hardware did not), by reading in Blocks 4-7 and transfering
to the loaded value. RC10, RH10, TM10 support readin mode.
The RP10 supports boot (actual hardware did not), by reading in Blocks 4-7
and transfering to the loaded value. RC10, RH10, TM10 support readin mode.
Todo:
RH10 TM03
@ -38,51 +40,61 @@ Todo:
Finish KI10 support.
Possibly add in support for KL10A. (No extended addressing).
# IBM 7000 simulators.
Latest status for I7000 Cpus:
i701: Largely untested.
## i701
i704: SAP works.
Fort2 unfinished.
* Largely untested.
i7010: Protection mode has some errors left.
Protection mode does not handle setting H or L to 0.
T020 tape diags fail.
Disks may work.
PR108 not tested.
## i704
* SAP works.
* Fort2 unfinished.
i7070: Will load Diags, need to remember how to run them to run
tests on machine.
## i7010
* Protection mode has some errors left.
* Protection mode does not handle setting H or L to 0.
* T020 tape diags fail.
* Disks may work.
* PR108 not tested.
i7080: Sort of working.
RWW, ECB untested.
TLx instructions implimented, untested, see 8SE
Will boot from card.
Tape system appear to be working.
Tape system will not pass diags.
## i7070
* Will load Diags, need to remember how to run them to run
* tests on machine.
8CU10B errors:
410, 412, 413, 414, 418, 419, 420-427 error becuase
storage is not parity checked.
440 divide not producing correct sign on error.
## i7080
* Sort of working.
* RWW, ECB untested.
* TLx instructions implimented, untested, see 8SE
* Will boot from card.
* Tape system appear to be working.
Tape system will not pass diags.
i7090: Working with exceptions.
Known bugs:
* 8CU10B errors:
410, 412, 413, 414, 418, 419, 420-427 error becuase
storage is not parity checked.
440 divide not producing correct sign on error.
DFDP/DFMP Sometimes off by +/-1 or 2 in least signifigant
part of result.
## i7090
* Working with exceptions.
HTx Not sure what problems are, does not quite work.
Known bugs:
DKx Sometimes fails diagnostics with missing inhibit of
interrupt.
DFDP/DFMP Sometimes off by +/-1 or 2 in least signifigant
part of result.
CTSS works.
HTx Not sure what problems are, does not quite work.
DKx Sometimes fails diagnostics with missing inhibit of
interrupt.
* CTSS works.
* Signifigence mode Not tested, Test Code Needed.
IOMC diag codes:
first keys 403030 and 001717 does channel E
first keys 203030 test channel A
016000200000 for disk test chan D
Signifigence mode Not tested, Test Code Needed.
IOMC diag codes:
first keys 403030 and 001717 does channel E
first keys 203030 test channel A
016000200000 for disk test chan D