- Recent changes in vax_watch.c changed the input parameter from a physical address to a register address within the watch chip. - vax630_sysdev.c called the older wtc_wr() with the new parameter, but the length argument has been removed. - The watch chip never starts as valid. Make it valid when the TODR is attached (i.e. reflecting a connected battery). - 64 bytes of bus addresses for the watch chip can sometimes be dispatched to wtc_rd() and wtc_wr(). Make sure that reasonable memory is always referenced for all potential accesses. - restore vax8200 to makefile which got lost in a prior merge.