;DIAGNOSTIC CONSOLE HELP FILE, KLDCP.HLP, VER 20.7, 8-JANUARY-76
|
||
|
||
A. DIAGNOSTIC FUNCTIONS
|
||
|
||
1. FX FUNCT ;DIAGNOSTIC FUNCTION EXECUTE
|
||
2. FW FUNCT:DATA ;DIAGNOSTIC FUNCTION WRITE
|
||
3. FR FUNCT ;DIAGNOSTIC FUNCTION READ
|
||
4. FR FUNCT1,FUNCTX ;DIAGNOSTIC FUNCTION BLOCK READ
|
||
5. FS ;DIAGNOSTIC FUNCTION SYNC
|
||
6. DA DATA ;DIAGNOSTIC DEPOSIT INTO AR
|
||
|
||
B. PDP-11 FUNCTIONS
|
||
|
||
1. SE ADR ;START 11 AT ADR
|
||
SED ;START 11 DIAGNOSTIC (ADDRESS = 3000)
|
||
SED # ;START 11 DIAGNOSTIC, RUN #PASSES
|
||
2. EE ADR ;EXAMINE 11 AT ADR AND PRINT
|
||
3. DE ADR:DATA ;DEPOSIT DATA IN 11 ADDRESS
|
||
4. EB ADR ;EXAMINE 11 BYTE AT ADR AND PRINT
|
||
5. DB ADR:DATA ;DEPOSIT 11 BYTE AT 11 ADDRESS
|
||
6. ZE ADR,ADR ;ZERO 11 MEMORY FROM ADR TO ADR
|
||
|
||
C. PDP-10 EXAMINE/DEPOSIT FUNCTIONS
|
||
|
||
1. EM ADR ;EXAMINE PDP-10 AT ADR AND PRINT
|
||
2. DM ADR:DATA ;DEPOSIT DATA IN PDP-10 ADDRESS
|
||
3. EN ;EXAMINE AND PRINT NEXT PDP-10 ADDRESS
|
||
4. DN DATA ;DEPOSIT DATA INTO NEXT PDP-10 ADDRESS
|
||
5. MZ ADR,COUNT ;MEMORY ZERO PDP-10
|
||
|
||
D. START/STOP FUNCTIONS
|
||
|
||
1. SP ;STOP 10, CLEAR RUN FLOP
|
||
2. RN ;START 10, SET RUN FLOP
|
||
3. SI ;SINGLE INSTRUCT, PUSH CONTINUE BUTTON
|
||
SI NUM ;DO NUM SINGLE INSTRUCTS
|
||
4. SIP ;SINGLE INSTRUCT & TRACE PRINT
|
||
5. PL ;PULSE CLOCK
|
||
6. PL NUM ;DO NUM CLOCKS
|
||
7. BU ;BURST CLOCK ONCE
|
||
8. SM NUM ;BURST CLOCK NUM
|
||
9. SM ;START MICRO-CODE
|
||
10. ST ADR ;START 10 AT ADDRESS
|
||
ST ;START 10 AT PREVIOUSLY SUPPLIED ADDRESS
|
||
STD ;START 10 DIAGNOSTIC, (EPT ADR = 440)
|
||
STD # ;START 10 DIAGNOSTIC, RUN # PASSES
|
||
STL ;START 10 LOADER, (EPT ADR = 442)
|
||
DDT ;START 10 DDT, (EPT ADR = 441)
|
||
STM ;START 10 MONITOR, (EPT ADR = 443)
|
||
11. MC ;PDP-10 MONITOR MODE CONTINUE
|
||
12. SW DATA ;SET 10'S SWITCH REGISTER
|
||
13. SW ;PRINT PRESENT 10'S SWITCH REGISTER
|
||
14. AC BLK ;REPORT & SELECT CURRENT AC BLOCK
|
||
15. AC BLK NUM ;SELECT CURRENT AC BLOCK
|
||
16. EP COUNT ;SET "EOP" INTERVAL COUNT
|
||
|
||
E. RAM FUNCTIONS
|
||
|
||
1. EC ADR ;EXAMINE C-RAM AT ADDRESS AND PRINT
|
||
2. DC ADR:DATA ;DEPOSIT DATA INTO C-RAM ADDRESS
|
||
3. RC ADR ;READ C-RAM BY DIAGNOSTIC FUNCTIONS
|
||
4. ED ADR ;EXAMINE D-RAM AT ADDRESS AND PRINT
|
||
5. DD ADR:DATA ;DEPOSIT DATA INTO D-RAM ADDRESS
|
||
6. MM ADR ;SYNC MARK MICRO-CODE, SET BIT 78
|
||
7. MU ADR ;SYNC UNMARK MICRO-CODE, CLEAR BIT 78
|
||
8. MT ADR:DATA ;CHANGE MICRO-CODE TIME FIELD, DATA=0-3
|
||
|
||
F. PDP-10 INSTRUCTION EXECUTE
|
||
|
||
1. EX INST ;EXECUTE 36 BIT INSTRUCTION
|
||
2. EXP INST ;EXECUTE & PRINT INSTRUCTION
|
||
3. EXT INST ;EXECUTE & TRACE SETUP INSTRUCTION
|
||
|
||
G. MASTER RESET
|
||
|
||
1. MR ;MASTER RESET
|
||
|
||
H. CLOCK OPERATIONS
|
||
|
||
1. CS NUM ;SELECT CLOCK SOURCE USING NUM CODE
|
||
; 0=NORMAL CLOCK
|
||
; 1=SPEED MARGIN CLOCK
|
||
; 2=EXTERNAL CLOCK
|
||
2. CR NUM ;SELECT CLOCK RATE USING NUM CODE
|
||
; 0=NORMAL
|
||
; 1=DIVIDE BY 2
|
||
; 2=DIVIDE BY 4
|
||
; 3=DIVIDE BY 8
|
||
|
||
I. PROCESSOR PARITY FUNCTIONS
|
||
|
||
1. PE ;REPORT PROCESSOR PARITY STOP CODE
|
||
2. PE NUM ;ENABLE PROCESSOR PARITY STOPS
|
||
3. PD ;DISABLE PROCESSOR PARITY STOPS
|
||
|
||
J. CACHE OPERATIONS
|
||
|
||
1. CE ;REPORT CACHE ENABLE CODE
|
||
2. CE NUM ;SELECT CACHE ENABLE OPTION
|
||
3. CI ;CACHE INVALIDATE
|
||
4. CF ;CACHE FLUSH
|
||
|
||
K. INTERNAL EBOX REGISTER READ FUNCTIONS
|
||
|
||
1. AR ;READ & PRINT AR REGISTER
|
||
2. BR ;READ & PRINT BR REGISTER
|
||
3. MQ ;READ & PRINT MQ REGISTER
|
||
4. FM ;READ & PRINT FM REGISTER
|
||
5. AD ;READ & PRINT ADDER
|
||
6. ARX ;READ & PRINT EXTENDED AR REGISTER
|
||
7. BRX ;READ & PRINT EXTENDED BR REGISTER
|
||
8. ADX ;READ & PRINT EXTENDED ADDER
|
||
9. PC ;READ & PRINT PC
|
||
10. VMA ;READ & PRINT VMA
|
||
11. VMH ;READ & PRINT VMA HELD
|
||
12. SC ;READ & PRINT SC REGISTER
|
||
13. FE ;READ & PRINT FE REGISTER
|
||
14. ERG ;READ & PRINT E-BUS REGISTER
|
||
15. ADB ;READ & PRINT ADDRESS BREAK
|
||
16. PI ;READ & PRINT PI SYSTEM
|
||
17. ALL ;PRINT ALL, C-RAM & REGISTERS
|
||
|
||
L. CONSOLE (TTY) CONTROL FUNCTIONS
|
||
|
||
1. TP NUM ;SET TTY PAGE LENGTH
|
||
2. TW NUM ;SET TTY PAGE WIDTH
|
||
3. TF NUM ;SET TTY FILL CLASS
|
||
|
||
4. TT ;SWITCH TO REMOTE TTY OPERATION
|
||
|
||
5. KLINIK ;REMOTE FS TTY ENABLE/DISABLE
|
||
|
||
6. LP ;LINE PRINTER SELECTION
|
||
|
||
M. PROGRAM LOADING CONTROL FUNCTIONS
|
||
|
||
1. DT NUM ;SELECT DECTAPE LOAD MODE,
|
||
;NUM IS DECTAPE UNIT
|
||
2. RP NUM ;SELECT RP04 LOAD MODE,
|
||
;NUM IS RP04 UNIT
|
||
4. RX NUM ;SWITCH TO FLOPPY LOAD MODE,
|
||
;NUM IS FLOPPY UNIT
|
||
4. AT ;SWITCH TO APT10 LOAD MODE
|
||
5. DI ;DIRECTORY, DECTAPE/FLOPPY/RP04
|
||
|
||
N. PDP-11 BREAKPOINT OPERATIONS
|
||
|
||
1. BP ;PRINT ACTIVE BREAKPOINTS
|
||
2. BP ADR ;SET A BREAKPOINT AT ADDRESS
|
||
|
||
3. RG ;PRINT REGISTERS SAVED AT BREAKPOINT,
|
||
;ERROR HALT, PRG HALT OR FATAL HALT.
|
||
|
||
4. BC ;BREAKPOINT CONTINUE
|
||
5. BC COUNT ;BP CONTINUE FOR COUNT
|
||
|
||
6. RB ;REMOVE CURRENT BP
|
||
7. RB 0 ;REMOVE ALL BP'S
|
||
8. RB ADR ;REMOVE BP AT ADDRESS
|
||
|
||
O. CONSOLE REINITIALIZATION
|
||
|
||
1. RI ;REINITIALIZE CONSOLE
|
||
|
||
P. ERROR HALT CONTINUE
|
||
|
||
1. HC ;CONTINUE FROM ERROR OR PROGRAM HALT
|
||
|
||
Q. REPEAT OPERATORS
|
||
|
||
1. R ;IF THIS IS THE FIRST COMMAND IN A
|
||
;COMMAND LINE, REPEAT THE COMMAND STRING
|
||
;CONTINUOUSLY. CONTROL C (↑C) RETURNS
|
||
;TO CONSOLE COMMAND MODE.
|
||
|
||
2. RP ;AS "R" COMMAND EXCEPT PRINTS THE DATA
|
||
;READ FOR READ TYPE COMMANDS.
|
||
|
||
3. TD COUNT ;PERFORM SPECIFIED TIME DELAY
|
||
|
||
R. KL10 MONITOR COMMANDS
|
||
|
||
1. B ;BOOT SYSTEM, RUNS "B.CMD" AS "J" FILE
|
||
2. LI ;LOGIN
|
||
3. H ;HELP, PRINT "KLDCP.HLP"
|
||
4. H FILE.EXT ;HELP, PRINT REQUESTED FILE
|
||
5. P FILE.EXT ;LOAD REQUESTED PROGRAM
|
||
;EXTENSIONS ARE:
|
||
; .RAM = KL10 C-RAM & D-RAM
|
||
; .BIN = PDP-11 BINARY
|
||
; .A11 = PDP-11 ASCIIZED BINARY
|
||
; .A10 = PDP-10 ASCIIZED SAVE FILE
|
||
; .SAV = PDP-10 SAVE FILE, ACT10 ONLY
|
||
; DEFAULT EXTENSION IS ".A10"
|
||
6. LT FILE.EXT ;LOAD PDP-10 ".A10" PROGRAM
|
||
7. LE FILE.EXT ;LOAD PDP-11 ".A11" PROGRAM
|
||
8. LB FILE.EXT ;LOAD PDP-11 ".BIN" PROGRAM
|
||
9. LR FILE.EXT ;LOAD KL10 ".RAM" C-RAM & D-RAM
|
||
10. V FILE.EXT ;VERIFY REQUESTED PROGRAM, AS "P" EXCEPT
|
||
;CURRENT FILE IS VERIFIED AGAINST
|
||
;FILE BEING READ.
|
||
N/A 11. S FILE.EXT ;RUN REQUESTED SCRIPT
|
||
N/A 12. M FILE.EXT ;RUN REQUESTED MASTER SCRIPT
|
||
13. C MESSAGE ;COMMENT/CORRECTIVE ACTION
|
||
R. KL10 MONITOR COMMANDS
|
||
|
||
14. GO ;GO START PROGRAM JUST LOADED
|
||
15. LO ;LOGOUT
|
||
N/A 16. GS FILE.EXT ;GENERATE GIVEN SCRIPT
|
||
17. CD FILE.EXT SRTADR,ENDADR
|
||
;PDP-11 CORE DUMP TO DTA, RP04, ACT10
|
||
; DEFAULT EXTENSION IS ".A11"
|
||
18. T ;REQUEST TIME
|
||
19. BT ;BOOT TEN, RUNS "BT.CMD" AS "J" FILE
|
||
20. ; ;LOCAL COMMENT
|
||
21. I FILE.EXT ;INDIRECT COMMAND FILE PROCESS
|
||
; DEFAULT EXTENSION IS ".CCL"
|
||
22. J FILE.EXT ;DOUBLE INDIRECT COMMAND FILE PROCESS
|
||
; DEFAULT EXTENSION IS ".CMD"
|
||
23. JC ;CONTINUE INTERRUPTED J FILE PROCESS
|
||
24. JR ;REPEAT PREVIOUS "J" COMMAND & CONTINUE
|
||
25. TA FILE.EXT ;TRANSFER FILE FROM ACT10 TO RP04
|
||
26. WF FILE.EXT ;WRITE FILE FROM DECTAPE/FLOPPY TO RP04
|
||
27. RENM:FILE.EXT FILE1.EXT
|
||
;RENAME RP04 FILE FROM FILE.EXT TO
|
||
;FILE1.EXT
|
||
28. DTCOPY ;COPY AND VERIFY DECTAPES
|
||
29. RXCOPY ;COPY AND VERIFY FLOPPY DISKETTES
|
||
DTE20 DEVICE REGISTER AND BIT DEFINITIONS, 18-NOV-75
|
||
|
||
DTEADR= 174400 ;ADDRESS OF (FIRST) DTE20 DEVICE REGISTER BLOCK
|
||
DTESIZ= 000040 ;SPACING BETWEEN CONSECUTIVE DTE20'S
|
||
DTEMAX= 4 ;MAXIMUM NUMBER OF DTE20'S ON ONE PDP-11
|
||
|
||
;OFFSETS FROM THE BASE OF THE DTE20 DEVICE REGISTER BLOCK
|
||
;TO SPECIFIC 10/11 INTERFACE RAM LOCATIONS AND REGISTERS.
|
||
|
||
DLYCNT= 00 ;DELAY COUNT (ADDRESS XXXX00)
|
||
DEXWD3= 02 ;DEPOSIT OR EXAMINE WORD 3 (ADDRESS XXXX02)
|
||
DEXWD2= 04 ;DEPOSIT OR EXAMINE WORD 2 (ADDRESS XXXX04)
|
||
DEXWD1= 06 ;DEPOSIT OR EXAMINE WORD 1 (ADDRESS XXXX06)
|
||
TENAD1= 10 ;10 ADDRESS WORD 1 FOR DEX (ADDRESS XXXX10)
|
||
TENAD2= 12 ;10 ADDRESS WORD 2 FOR DEX (ADDRESS XXXX12)
|
||
TO10BC= 14 ;TO10 BYTE COUNT (ADDRESS XXXX14)
|
||
TO11BC= 16 ;TO11 BYTE COUNT (ADDRESS XXXX16)
|
||
TO10AD= 20 ;TO10 PDP11 MEMORY ADDRESS (ADDRESS XXXX20)
|
||
TO11AD= 22 ;TO11 PDP11 MEMORY ADDRESS (ADDRESS XXXX22)
|
||
TO10DT= 24 ;TO10 PDP11 DATA WORD (ADDRESS XXXX24)
|
||
TO11DT= 26 ;TO11 PDP11 DATA WORD (ADDRESS XXXX26)
|
||
|
||
DIAG1= 30 ;DIAGNOSTIC WORD 1 (ADDRESS XXXX30)
|
||
DIAG2= 32 ;DIAGNOSTIC WORD 2 (ADDRESS XXXX32)
|
||
STATUS= 34 ;10/11 INTERFACE STATUS WORD (ADDRESS XXXX34)
|
||
DIAG3= 36 ;DIAGNOSTIC WORD 3 (ADDRESS XXXX36)
|
||
|
||
; THE FOLLOWING ARE THE ADDRESSES OF THE DTE20 INTERRUPT VECTORS
|
||
|
||
DTEIV0= 774 ;INTERRUPT VECTOR FOR DTE20 #0
|
||
DTEIV1= 770 ;INTERRUPT VECTOR FOR DTE20 #1
|
||
DTEIV2= 764 ;INTERRUPT VECTOR FOR DTE20 #2
|
||
DTEIV3= 760 ;INTERRUPT VECTOR FOR DTE20 #3
|
||
|
||
;CLOCK CONTROL FUNCTIONS
|
||
|
||
STPCLK= 000 ; STOP CLOCK
|
||
STRCLK= 001 ; START CLOCK
|
||
SSCLK= 002 ; SINGLE STEP THE MBOX CLOCK
|
||
SECLK= 003 ; SINGLE STEP EBOX CLOCK
|
||
CECLK= 004 ; CONDITIONAL EBOX CLOCK
|
||
CLRMR= 006 ; CLEAR MR RESET
|
||
SETMR= 007 ; SET MR RESET
|
||
BRCLK= 005 ; BURST THE CLOCK
|
||
|
||
;CLOCK LOAD FUNCTIONS
|
||
|
||
LDBRR= 42 ; LOAD BURST REGISTER RIGHT HALF
|
||
LDBRL= 43 ; LOAD BURST REGISTER LEFT HALF
|
||
LDSEL= 44 ; LOAD SOURCE AND RATE SELECTS
|
||
LDDIS= 45 ; LOAD EBOX CLOCK DISTRIBUTION REGISTER
|
||
LDCHK1= 46 ; LOAD PARITY CHECK REGISTER (ENABLE BAD PARITY STOP)
|
||
LDCHK2= 47 ; LOAD EBOX INTERNAL CHECK REGISTER
|
||
|
||
;DRAM FUNCTIONS
|
||
|
||
LDRAM1= 60 ; LOAD A & B FIELDS EVEN
|
||
LDRAM2= 61 ; LOAD A & B FIELDS ODD
|
||
LDRAM3= 62 ; LOAD COMMON J1-J4
|
||
LDRJEV= 63 ; LOAD PARITY & J8-J10 EVEN
|
||
LDRJOD= 64 ; LOAD PARITY & J8-J10 ODD
|
||
DRAMAB= 133 ; READ D-RAM A & B
|
||
DRJ710= 135 ; READ D-RAM J7-J10
|
||
DRJ1.4= 134 ; READ D-RAM J1-J4
|
||
|
||
;IR DRAM CONTROL
|
||
|
||
DISIOJ= 65 ; DISABLE 7XX & JRST=254
|
||
DISACF= 66 ; DISABLE THE IR AC'C
|
||
ENIOJA= 67 ; ENABLE 7XX, JRST=254 & IR AC'S
|
||
|
||
;CRAM FUNCTIONS
|
||
|
||
LCRAM1= 71 ; LOAD C-RAM DATA
|
||
LCRAM2= 56
|
||
LCRAM3= 55
|
||
LCRAM4= 54
|
||
LCRAM5= 53
|
||
LCRDAL= 51 ; LOAD CRAM ADDRESS LEFT (00-04)
|
||
LCRDAR= 52 ; LOAD CRAM ADDRESS RIGHT (05-10)
|
||
RCRAM1= 147 ; READ C-RAM DATA
|
||
RCRAM2= 146
|
||
RCRAM3= 145
|
||
RCRAM4= 144
|
||
|
||
;MISC CONTROL FUNCTIONS
|
||
|
||
IRLOAD= 14 ; LOAD THE IR FROM AD
|
||
DRLTCH= 15 ; LOAD D-RAM LATCHES
|
||
CLRRUN= 10 ; CLEAR RUN FLIP-FLOP
|
||
SETRUN= 11 ; SET RUN FLIP-FLOP
|
||
CONBUT= 12 ; THE CONTINUE BUTTON
|
||
LDAR= 77 ; LOAD THE AR
|
||
|
||
;MBOX CONTROL FUNCTIONS
|
||
|
||
LDMBXA= 57 ; LOAD MEMORY TO CACHE SELECTOR
|
||
LDCHAN= 70 ; LOAD CHANNEL DIAGNOSTIC CONDITIONS
|
||
|
||
;PI CONTROL FUNCTIONS
|
||
|
||
READ0= 100 ; PI (READ STATUS 0)
|
||
READ1= 101 ; PI (READ STATUS 1)
|
||
READ2= 102 ; PI (READ STATUS 2)
|
||
READ3= 103 ; PI (READ STATUS 3)
|
||
|
||
;DATA PATH CONTROL FUNCTIONS
|
||
|
||
DPAR =120 ; AR
|
||
DPBR =121 ; BR
|
||
DPMQ =122 ; MQ
|
||
DPFM =123 ; FM
|
||
DPFMA =114 ; FM ADR
|
||
DPBRX =124 ; BRX
|
||
DPARX =125 ; ARX
|
||
DPADX =126 ; ADX
|
||
DPAD =127 ; AD
|
||
DPPC =153 ; PC
|
||
DPVMA =157 ; VMA
|
||
DPVMHD =157 ; VMA HELD
|
||
DPADB =153 ; ADDRESS BREAK
|
||
DPERG =167 ; E-BUS REGISTER
|
||
DPFE =132 ; FE 05-09
|
||
DPFE1 =133 ; FE 00-04
|
||
DPSC =130 ; SC 05-09
|
||