Some changes to data update

This commit is contained in:
Gunnar Skjold 2024-09-21 13:00:22 +02:00
parent ada57b1052
commit 0b342d6c49

View File

@ -1363,28 +1363,31 @@ void handleDataSuccess(AmsData* data) {
meterState.apply(*data);
rtp.update(meterState);
time_t dataUpdateTime = now;
if(abs(now - meterTime) < 300) {
dataUpdateTime = meterTime;
}
tmElements_t tm, mtm;
breakTime(now, tm);
breakTime(meterTime, mtm);
bool saveData = false;
if(!ds.isHappy(now) && now > FirmwareVersion::BuildEpoch) { // Must use "isHappy()" in case day state gets reset and lastTimestamp is "now"
tmElements_t tm, mtm;
breakTime(now, tm);
breakTime(meterTime, mtm);
if(!wasCounterEstimated) { // Assuming these type of meters report all data all the time
if(tm.Minute == 0 && data->getListType() == 3) {
debugD_P(PSTR("Updating data storage (internal clock %02d:%02d:%02d UTC, meter clock: %02d:%02d:%02d)"), tm.Hour, tm.Minute, tm.Second, mtm.Hour, mtm.Minute, mtm.Second);
saveData = ds.update(data, now);
}
} else if(data->getListType() == 3) { // Assuming HAN-NVE style meters which reports list type 3 only once per hour
if(tm.Minute == 0) {
debugD_P(PSTR("Updating data storage, triggered by internal clock %02d:%02d:%02d UTC (Meter clock: %02d:%02d:%02d)"), tm.Hour, tm.Minute, tm.Second, mtm.Hour, mtm.Minute, mtm.Second);
saveData = ds.update(data, now);
} else if(mtm.Minute == 0 && meterTime > FirmwareVersion::BuildEpoch) {
debugD_P(PSTR("Updating data storage, triggered by meter clock %02d:%02d:%02d UTC (Internal clock: %02d:%02d:%02d)"), mtm.Hour, mtm.Minute, mtm.Second, tm.Hour, tm.Minute, tm.Second);
saveData = ds.update(data, meterTime);
}
} else if(tm.Minute == 1) {
if(!ds.isHappy(dataUpdateTime) && dataUpdateTime > FirmwareVersion::BuildEpoch) { // Must use "isHappy()" in case day state gets reset and lastTimestamp is "now"
debugD_P(PSTR("READY to update (internal clock %02d:%02d:%02d UTC, meter clock: %02d:%02d:%02d, list type %d, est: %d, using clock: %d)"), tm.Hour, tm.Minute, tm.Second, mtm.Hour, mtm.Minute, mtm.Second, data->getListType(), wasCounterEstimated, dataUpdateTime == now);
tmElements_t dtm;
breakTime(dataUpdateTime, dtm);
if(dtm.Minute == 0 && data->getListType() >= 3) {
debugD_P(PSTR("Updating data storage using actual data"));
saveData = ds.update(data, dataUpdateTime);
#if defined(_CLOUDCONNECTOR_H)
if(saveData && cloud != NULL) cloud->forceUpdate();
#endif
} else if(dtm.Minute == 1) {
debugW_P(PSTR("Did not receive necessary data for previous hour, clearing"));
AmsData nullData;
saveData = ds.update(&nullData, now);
saveData = ds.update(&nullData, dataUpdateTime);
}
if(saveData) {
debugI_P(PSTR("Saving data"));
@ -1392,12 +1395,10 @@ void handleDataSuccess(AmsData* data) {
debugW_P(PSTR("Unable to save data storage"));
}
}
} else {
debugD_P(PSTR("NOT Ready to update (internal clock %02d:%02d:%02d UTC, meter clock: %02d:%02d:%02d, list type %d, est: %d)"), tm.Hour, tm.Minute, tm.Second, mtm.Hour, mtm.Minute, mtm.Second, data->getListType(), wasCounterEstimated);
}
#if defined(_CLOUDCONNECTOR_H)
if(saveData && cloud != NULL) cloud->forceUpdate();
#endif
if(ea.update(data)) {
debugI_P(PSTR("Saving energy accounting"));
if(!ea.save()) {