Fix on special case for Kaifa MA304T3

This commit is contained in:
Gunnar Skjold 2022-12-06 08:28:30 +01:00
parent 1ef5703971
commit a239e1a63d

View File

@ -98,8 +98,10 @@ IEC6205675::IEC6205675(const char* d, uint8_t useMeterType, MeterConfig* meterCo
}
if(listType >= 2 && memcmp(meterModel.c_str(), "MA304T3", 7) == 0) {
l2current = (((activeImportPower - activeExportPower) * sqrt(3)) - (l1voltage * l1current) - (l3voltage * l3current)) / l2voltage;
l2voltage = sqrt(pow(l1voltage - l3voltage * cos(60 * (PI/180)), 2) + pow(l3voltage * sin(60 * (PI/180)),2));
if(l2voltage > 0) {
l2current = (((activeImportPower - activeExportPower) * sqrt(3)) - (l1voltage * l1current) - (l3voltage * l3current)) / l2voltage;
}
}
if(listType == 3) {