2017-10-24 20:21:37 +02:00

1.9 KiB

One sample of each list on the Kamstrup ??? meter

For the data parts, I have found they follow a pattern where the first byte dictates the data type and size: 02 - one byte following 06 - long (4 bytes / 32 bits) 12 - int (2 bytes / 16 bit) 09 - string, first byte is length (could it be a byte array?) 0A - string, first byte is length

List #1 (0x19)

Data Explaination Value
E6 E7 00 0F 00 00 00 00 Uknown
09 0C 07 E1 0A 14 05 03 2B 1E FF 80 00 00 Date and time 2017-10-20 (fre) 03:43:30
02 19 List ID 25 (List 1)
0A 0E 4B 61 6D 73 74 72 75 70 5F 56 30 30 30 31 OBIS List Version Identifier Kamstrup_V0001
09 06 01 01 00 00 05 FF OBIS for Meter ID 1.1.0.0.5.255
0A 10 35 37 30 36 35 36 37 32 37 34 33 38 39 37 30 32 Meter ID 5706567274389702
09 06 01 01 60 01 01 FF OBIS for Meter Type 1.1.96.1.1.255
0A 12 36 38 34 31 31 32 31 42 4E 32 34 33 31 30 31 30 34 30 Meter Type 6841121BN243101040
09 06 01 01 01 07 00 FF OBIS for Active Power + 1.1.1.7.0.255
06 00 00 05 BC Active Power + 1468 W
09 06 01 01 02 07 00 FF OBIS for Active Power - 1.1.2.7.0.255
06 00 00 00 00 Active Power - 0 W
09 06 01 01 03 07 00 FF OBIS for Reactive Power + 1.1.3.7.0.255
06 00 00 00 00 Reactive Power + 0W
09 06 01 01 04 07 00 FF OBIS for Reactive Power - 1.1.4.7.0.255
06 00 00 01 CE Reactive Power - 462W
09 06 01 01 1F 07 00 FF OBIS for L1 Current 1.1.31.7.0.255
06 00 00 02 34 L1 Current 5.64 A
09 06 01 01 33 07 00 FF OBIS for L2 Current 1.1.51.7.0.255
06 00 00 00 CA L2 Current 2.02 A
09 06 01 01 47 07 00 FF OBIS for L3 Current 1.1.71.7.0.255
06 00 00 01 FF L3 Current 5.11 A
09 06 01 01 20 07 00 FF OBIS for L1 Voltage 1.1.32.7.0.255
12 00 E8 L1 Voltage 232 V
09 06 01 01 34 07 00 FF OBIS for L2 Voltage 1.1.52.7.0.255
12 00 E4 L1 Voltage 228 V
09 06 01 01 48 07 00 FF OBIS for L3 Voltage 1.1.72.7.0.255
12 00 E9 L1 Voltage 233 V