One sample of each list on the Kaifa MA304H3E meter
(Samples are captured from my meter and the breakdown and values are from . Please note that units and/or data types in this document doesn't seem to be right. E.g. my total meter reading is 403 kWh, not the tenfold. Hopefully, the current is also closer to 1A than 1000A in each wire)
For the data parts, I have found they follow a pattern where the first byte dictates the data type and size: 02 - one byte following 06 - long (4 bytes / 32 bits) 09 - string, first byte is length
List #1 (0x01) (time is 1506275242) consumption is 601 Watts
| Data | Explaination | Value |
|---|---|---|
| E6 E7 00 0F 40 00 00 00 | Uknown | |
| 09 0C 07 E1 09 18 07 11 2F 16 FF 80 00 00 | Date and time | 2017-09-24 17:47:22 |
| 02 01 | List (02) of 1 elements (01) following | 0x01 = one element |
| 06 00 00 02 59 | Active power+ (Q1+Q4) | 0.601 kW |
List #2 (0x0D) (time is 1506275240)
| Data | Explaination | Value |
|---|---|---|
| E6 E7 00 0F 40 00 00 00 | Unknown | |
| 09 0C 07 E1 09 18 07 11 2F 14 FF 80 00 00 | Date and time | 2017-09-24 17:47:20 (FF=hundreds not available, 8000=deviation, 00=status) |
| 02 0D | List (02) of 13 elements (0D) following | 0x0D = 13 elements |
| 09 07 4B 46 4D 5F 30 30 31 | OBIL List version identifier | KFM_001 |
| 09 10 36 39 37 30 36 33 31 34 30 31 37 35 33 39 38 35 | Meter -ID (GIAI GS1 -16 digit ) | 6970631401753985 |
| 09 08 4D 41 33 30 34 48 33 45 | Meter type | MA304H3E |
| 06 00 00 02 5C | Active power+ (Q1+Q4) | 0.604 kW |
| 06 00 00 00 00 | Active power - (Q2+Q3) | 0.000 kW |
| 06 00 00 00 00 | Reactive power + (Q1+Q2) | 0.000 kVAr |
| 06 00 00 01 19 | Reactive power - (Q3+Q4) | 0.281 kVAr |
| 06 00 00 06 BD | IL1 Current phase L1 | 1725 A |
| 06 00 00 05 BA | IL2 Current phase L2 | 1466 A |
| 06 00 00 08 86 | IL3 Current phase L3 | 2182 A |
| 06 00 00 09 60 | ULN1 Phase voltage 4W meter, Line voltage 3W meter | 2400 V |
| 06 00 00 00 00 | ULN2 Phase voltage 4W meter, Line voltage 3W meter | 0 V |
| 06 00 00 09 78 | ULN3 Phase voltage 4W meter, Line voltage 3W meter | 2424 V |
List #3 (0x12) (time is 1506247210)
| Data | Explaination | Value |
|---|---|---|
| E6 E7 00 0F 40 00 00 00 | Unknown | |
| 09 0C 07 E1 09 18 07 0A 00 0A FF 80 00 00 | Date and time | 2017-09-24 10:00:10 |
| 02 12 | List (02) of 18 elements (12) following | 0x12 = 18 elements |
| 09 07 4B 46 4D 5F 30 30 31 | OBIL List version identifier | KFM_001 |
| 09 10 36 39 37 30 36 33 31 34 30 31 37 35 33 39 38 35 | Meter -ID (GIAI GS1 -16 digit ) | 6970631401753985 |
| 09 08 4D 41 33 30 34 48 33 45 | Meter type | MA304H3E |
| 06 00 00 01 BA | Active power+ (Q1+Q4) | 0.442 kW |
| 06 00 00 00 00 | Active power - (Q2+Q3) | 0.000 kW |
| 06 00 00 00 00 | Reactive power + (Q1+Q2) | 0.000 kVAr |
| 06 00 00 01 01 | Reactive power - (Q3+Q4) | 0.257 kVAr |
| 06 00 00 04 92 | IL1 Current phase L1 | 1170 A |
| 06 00 00 05 94 | IL2 Current phase L2 | 1428 A |
| 06 00 00 05 A7 | IL3 Current phase L3 | 1447 A |
| 06 00 00 09 62 | ULN1 Phase voltage 4W meter, Line voltage 3W meter | 2402 V |
| 06 00 00 00 00 | ULN2 Phase voltage 4W meter, Line voltage 3W meter | 0 V |
| 06 00 00 09 73 | ULN3 Phase voltage 4W meter, Line voltage 3W meter | 2419 V |
| 09 0C 07 E1 09 18 07 0A 00 0A FF 80 00 00 | Clock and date in meter | 2017-09-24 10:00:10 |
| 06 00 06 27 21 | Cumulative hourly active import energy (A+) (Q1+Q4) | 403 233 kWh |
| 06 00 00 00 00 | Cumulative hourly active export energy (A-) (Q2+Q3) | 0 kWh |
| 06 00 00 03 5A | Cumulative hourly reactive import energy (R+) (Q1+Q2) | 858 kWh |
| 06 00 00 DA AE | Cumulative hourly reactive export energy (R-) (Q3+Q4) | 55 982 kWh |