1
0
mirror of https://github.com/wfjm/w11.git synced 2026-02-14 04:04:42 +00:00
Files
wfjm.w11/doc/simh_diff_service-order.md
2022-12-21 12:58:05 +01:00

1.1 KiB

Known differences between SimH, 11/70, and w11a

SimH: trap and interrupt service order has J11 behavior

The 11/70 (and the 11/45) differ from all other PDP-11 models in the order in which interrupts and traps are honored after the successful completion of an instruction. On the 11/70, interrupts have precedence over T-bit trace traps, on all other models interrupts have the lowest priority.

As consequence, RTI can be used on an 11/70 to exit from an interrupt driver, and exactly one trace trap will happen when an interrupt is honored after a traced instruction. On all other models, RTT should be used to exit from an interrupt driver to prevent a double trace trap, one before the interrupt and one after the hander exit.

SimH uses the J11 service order with interrupts having the lowest priority for all PDP-11 models.

The w11 implements the 11/70 service order. This is verified in a tcode, the test is skipped when executed on SimH (see cpu_details.mac test A4.4 part 3).