Known differences between w11a and KB11-C (11/70)

MMR0 instruction complete implementation differences

The 11/70 and 11/45 are the only PDP-11 processors that also support the recovery of an MMU abort of a stack push during trap or interrupt processing. To distinguish between an instruction and a trap processing abort, the MMR0 has a bit called instruction completed. It is set to 0 when an instruction is aborted and to 1 when a vector service flow is aborted. The MMR2 contains the vector address in the latter case.

w11 supports this feature, but has two implementation differences:

  • the instruction completed flag is set and MMR2 is loaded with the vector address for all vector flows. The 11/70 does this only for traps, aborts and interrupts, but not for trap instructions (BPT, IOT, TRAP, EMT).
  • the w11 decrements the SP before each vector push, while the 11/70 decrements the SP twice before the 1st vector push. Therefore, after an MMU abort of the 1st vector push, MMR1 has 000336 on the w11 and 173366 on the 11/70. xxdp program ekbee1 test 067 checks this MMR1 response and has been modified (see patch).